Datasheet

32
Replacing the Chassis Cover
78-4519-04
Removing and Installing the Cisco AS5350 Power Supply
Step 6 Reinstall the chassis on a rack, desktop, or table.
Step 7 Reinstall all interface cables.
Step 8 Reconnect the AC power cords. Or, if you are using a DC-powered unit, refer to Figure 37 and Figure 38,
and complete Step a through Step e.
Warning
The illustration shows the DC power supply terminal block. Wire the DC power supply using the
appropriate wire terminations at the wiring end, as illustrated. The proper wiring sequence is ground
to ground, return to return, and negative to negative. Note that the ground wire should always be
connected first and disconnected last. To see translations of the warnings that appear in this
publication, refer to the Regulatory Compliance and Safety Information document that accompanied
this device.
Figure 37 Connecting DC Power Supply—Single Power Supply
Caution Do not overtorque the terminal block contact screws. The recommended torque is 4.5 lb-in. (0.50 N-m).
Figure 35Power Ratings Label for DC Power Supply
INPUT -48/-60V == 3A 150VA
Figure 36Power Ratings Label for AC Power Supply
INPUT 100 – 240V~ 50/60Hz 2 – 1A
56022
Power switch
Source A - NEG
Source A - RTN
Source B - NEG
Source B - RTN
Ground
To DC source
DC connector