Spec Sheet Cisco UCS C22 M3 High-Density Rack-Mount Server (Small Form Factor Hard Disk Drive Model) CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV B.
CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 BASE SERVER STANDARD CAPABILITIES and FEATURES . .
OVERVIEW OVERVIEW The Cisco® UCS C22 M3 small form factor (SFF) drive Rack Server combines economics and a density-optimized feature set from entry level enterprise to SMB with applications such as scale out, virtualization, IT and web infrastructure, VPN servers, file/print servers, and appliances.
DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C22 M3 High-Density SFF Rack Server. 1 Chassis Front View 2 3 4 5 6 HDD04 7 8 HDD01 HDD06 HDD05 9 HDD02 HDD07 HDD03 HDD08 10 1 Power button/power status LED 6 Power supply status LED 2 Identification button/LED 7 Network link activity LED 3 System status LED 8 USB 2.
DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel.
BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER, page 9.
BASE SERVER STANDARD CAPABILITIES and FEATURES Capability/Feature Description Storage controller The following RAID options are available: ■ Embedded RAID (3 Gbps) (these implementations of RAID do not consume a PCIe slot). • Embedded SATA-only RAID controller, supporting up to four SATA-only drives (RAID 0, 1, 10), or • ROM5 RAID upgrade, supporting up to eight SAS+SATA drives (RAID 0, 1, 10), or • ROM55 RAID upgrade, supporting up to eight SAS+SATA drives (RAID 0, 1, 5, 10).
BASE SERVER STANDARD CAPABILITIES and FEATURES Capability/Feature Description Integrated management processor Cisco Integrated Management Controller (CIMC). Depending on your CIMC settings, the CIMC can be accessed through the 1-Gb Ethernet dedicated management port, the 1-Gb Ethernet LOM ports, or a Cisco 1225 virtual interface card. Notes . . . 1. NCSI = network communications services interface protocol. The slot stays active when the server is in standby power state. 2.
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C22 M3 High-Density SFF Rack Server: ■ STEP 1 VERIFY SERVER SKU, page 10 ■ STEP 2 SELECT CPU(s), page 11 ■ STEP 3 SELECT MEMORY, page 13 ■ STEP 4 SELECT RAID CONFIGURATION, page 17 ■ STEP 5 SELECT DRIVES, page 22 ■ STEP 6 SELECT PCIe OPTION CARD(s), page 24 ■ STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 26 ■ STEP 8 SELECT AC POWER CORD(s), page 30 ■ STEP 9 ORDER POWER SUPPLY, page 33 ■ STE
CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Verify the product ID (PID) of the server as shown in Table 2. Table 2 PID of the C22 M3 High-Density SFF Rack Base Server Product ID (PID) UCSC-C22-M3S Description UCS C22 M3 SFF with rail kit, without PSU, CPU, memory, HDD, SSD, or PCIe cards The Cisco C22 M3 server: ■ Includes a rail kit (UCSC-RAIL1) ■ Does not include power supply, CPU, memory, hard disk drives (HDDs), solid state drives (SSDs), or plug-in PCIe cards.
CONFIGURING the SERVER STEP 2 SELECT CPU(s) The standard CPU features are: ■ Intel Xeon E5-2400 v2 or E5-2400 series processor family CPUs ■ Intel C600 chipset ■ Cache size of up to 25 MB Select CPUs The available CPUs are listed in Table 3. Table 3 Available Intel CPUs: Xeon E5-24xx Family Intel Number Product ID (PID) Clock Freq (GHz) Power (W) Cache Size (MB) Cores QPI (GT/s) Highest DDR3 DIMM Clock Support (MHz)1 Intel Xeon E5-2400 v2 UCS-CPU-E52470B E52470 v2 2.4 95 25 10 8.
CONFIGURING the SERVER Approved Configurations (1) 1-CPU configurations: ■ Select any one CPU listed in Table 3. (2) 2-CPU Configurations: ■ Select two identical CPUs from any one of the rows of Table 3 on page 11. Caveats 12 ■ You can select either one CPU or two identical CPUs. ■ If you select one CPU, only one PCIe slot (the full-height slot on riser 1) is available for use. ■ For optimal performance, select DIMMs with the highest clock speed for a given processor (see Table 3 on page 11).
CONFIGURING the SERVER STEP 3 SELECT MEMORY The standard memory features are: ■ ■ Figure 4 DIMMs — Clock speed: 1600 or 1333 MHz — Ranks per DIMM: 1, 2, or 4 — Operational voltage: 1.35 V or 1.5 V — Registered ECC DDR3 DIMMS (RDIMMS), unregistered DIMMs (UDIMMs), or load-reduced DIMMs (LRDIMMs) Memory is organized with three memory channels per CPU, with up to two DIMMs per channel, as shown in Figure 4.
CONFIGURING the SERVER Select DIMMs Select the memory configuration. The available memory DIMMs are listed in Table 4. NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel.
CONFIGURING the SERVER Approved Configurations (1) 1-CPU configuration without memory mirroring: ■ Select from 1 to 6 DIMMs. Refer to Memory Population Rules, page 51, for more detailed information. (2) 1-CPU configuration with memory mirroring: ■ ■ Select either 2 or 4 DIMMs.
CONFIGURING the SERVER Caveats ■ Do not mix 1333 MHz and 1600 MHz DIMMs ■ Do not mix DIMM types (RDIMM, LRDIMM, or UDIMM) ■ Do not select more than two different types of DIMMs (only two PID types allowed) ■ For 2-CPU configurations, install a minimum of 2 DIMMs (one per CPU). ■ If you use different sizes of DIMMs, the quantity of each size of DIMM must be even (2, 4, or 6). For example, 4 UCS-MR-1X082RY-A DIMMs and 6 UCS-MR-1X162RY-A DIMMs.
CONFIGURING the SERVER STEP 4 SELECT RAID CONFIGURATION NOTE: If you do not select a PCIe RAID controller or one of the embedded RAID upgrade options, you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10) NOTE: When creating a RAID volume, follow these guidelines: ■ Use the same capacity for each drive in the volume ■ Use either all SAS drives or all SATA drives ■ Use either all HDDs or all SSDs NOTE: The number of RAID groups (virtual drives)
CONFIGURING the SERVER Select RAID Options Select one RAID controller (either embedded RAID in Table 5 or hardware RAID using a PCIe RAID controller and an appropriate RAID configuration option listed in Table 6 on page 18). Table 5 Available Embedded RAID (LSI MegaSR) Options Product ID (PID) PID Description Embedded RAID UCSC-RAID-ROM5 Onboard RAID, consisting of a plug-in storage controller unit (SCU), supporting up to 8 internal SAS +SATA drives. SAS and SATA drives can be mixed.
CONFIGURING the SERVER Table 6 Available Hardware RAID Options (continued) Product ID (PID) PID Description UCS-RAID9270CV-8i LSI MegaRAID 9270CV-8i (with supercap power backup) ■ Supports up to 8 internal SAS+SATA drives. SAS and SATA drives can be mixed.
CONFIGURING the SERVER Approved Configurations (1) 1-CPU Configurations Select an embedded RAID option from Table 5 on page 18 or one PCIe RAID controller from Table 6 on page 18. You may also select an appropriate optional RAID configuration listed in Table 6 on page 18. NOTE: In 1-CPU configurations, PCIe slot 1 is the default slot supported for an internal drive RAID controller. PCIe slot 2 is not supported for 1-CPU systems.
CONFIGURING the SERVER ■ — Note that only a single Cisco 1225 Virtual Interface Card (VIC) card is supported and it must be installed in the full-length, full-height PCIe slot (slot 1) on riser 1, which is the only slot that supports NCSI. So take this into account when populating RAID controller cards. You can have either a PCIe RAID controller or a VIC card in slot 1. — Slot 2 is not supported in 1-CPU systems.
CONFIGURING the SERVER STEP 5 SELECT DRIVES The standard disk drive features are: ■ 2.5-inch small form factor ■ Hot-pluggable ■ Sled-mounted Select Drives The available drives are listed in Table 7. Table 7 Available Hot-Pluggable Sled-Mounted HDDs or SSDs PID Description Drive Type Capacity UCS-HDD250G1F111 250 GB 6Gb SATA 7.2K RPM SATA 250 GB UCS-HDD300GI2F105 300 GB 6Gb SAS 15K RPM SFF SAS 300 GB A03-D300GA2 300 GB 6Gb SAS 10K RPM SFF SAS 300 GB A03-D500GC3 500 GB SATA 7.
CONFIGURING the SERVER NOTE: When creating a RAID volume, follow these guidelines: ■ Use the same capacity for each drive in the volume ■ Use either all SAS drives or all SATA drives ■ Use either all HDDs or all SSDs NOTE: The number of RAID groups (virtual drives) supported per controller is as follows: ■ LSI MegaRAID SAS 9270CV-8i RAID controller card = 64 ■ LSI MegaRAID 9240-8i RAID controller card = 16 ■ LSI MegaRAID 9220-8i RAID controller card = 16 Approved Configurations (1) Embedded RAI
CONFIGURING the SERVER STEP 6 SELECT PCIe OPTION CARD(s) The standard PCIe card offerings are: ■ Converged Network Adapters (CNAs) ■ Network Interface Cards (NICs) ■ Host Bus Adapters (HBAs) Select PCIe Option Cards The available PCIe option cards are listed in Table 8.
CONFIGURING the SERVER Approved Configurations (1) No PCIe RAID controller ■ If you did not choose a PCIe RAID controller (for example, you selected embedded RAID (LSI MegaSR) or no RAID controller at all), you can select up to one PCIe option card listed in Table 8 on page 24 for 1-CPU configurations or up to two cards for 2-CPU configurations.
CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server. Choose Optional Twinax Cables Table 9 lists the copper twinax cables available for the PCIe cards. You can choose cable lengths of 1, 3, 5, 7, or 10 meters.
CONFIGURING the SERVER Approved Configurations (1) Choose Up to Two SFP+ Modules for Each Network Card Ordered ■ You may choose one or two SFP+ optical modules cables for each compatible PCIe network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available. See the Figure 5 on page 29 for typical SFP+ and twinax connections to the network cards.
CONFIGURING the SERVER Table 11 PCIe Card Compatibility Cisco SFP Modules Twinax Cables SFP-10G-SR DS-SFP-FC8G-SW PCIe Cards Converged Network Adapters (CNAs) UCSC-PCIE-BSFP (Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI) UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) UCSC-PCIE-C10T-02 (Cisco VIC 1225T Dual Port 10GBaseT CNA) UCSC-PCIE-C40Q-02 (Cisco VIC 1285 Dual Port 40Gb QSFP CNA) UCSC-PCIE-C40Q-03 (Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA) UCSC-PCIE-ESFP (Emulex OCe11102-FX dual-port
CONFIGURING the SERVER Table 11 PCIe Card Compatibility (continued) Cisco SFP Modules Twinax Cables SFP-10G-SR DS-SFP-FC8G-SW PCIe Cards N2XX-AQPCI05 (QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA) UCSC-PCIE-Q2672 (Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics) UCSC-PCIE-E16002 (Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics) No Preinstalled - do not change SFP No Preinstalled - do not change SFP No Preinstalled - do not change SFP Notes . . . 1.
CONFIGURING the SERVER STEP 8 SELECT AC POWER CORD(s) Using Table 12, select the appropriate AC power cords. You can select a minimum of no power cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
CONFIGURING the SERVER Table 12 Available Power Cords Product ID (PID) PID Description SFS-250V-10A-AR Power Cord, SFS, 250V, 10A, Argentina Images 2500 mm Cordset rating: 10 A, 250/500 V MAX Length: 8.
CONFIGURING the SERVER Table 12 Available Power Cords Product ID (PID) PID Description CAB-9K10A-IT Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy Images Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector C15M (EN60320/C15 ) 186575 Plug: I/3G (CEI 23-16) CAB-9K10A-SW Power Cord, 250VAC 10A MP232 Plug, Switzerland Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.
CONFIGURING the SERVER STEP 9 ORDER POWER SUPPLY The C22 M3 server accommodates one power supply. A lightly loaded server can operate from one 450 W power supply. A fully loaded server might need to be powered with a 650 W power supply (see Table 13). Prior to making a power supply selection, the UCS Power Calculator should be run to determine the right size power supply for your server configuration. A fully configured C22 M3 server may require the 650 W power supply.
CONFIGURING the SERVER STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use Table 14 to order a cable management arm. Table 14 Cable Management Arm Product ID (PID) PID Description UCSC-CMA1 Cable Management Arm for C22 rack servers NOTE: If you order and install a cable management arm, you will need the longest power cable available.
CONFIGURING the SERVER STEP 11 ORDER A TRUSTED PLATFORM MODULE Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy.
CONFIGURING the SERVER STEP 12 ORDER OPTIONAL USB 2.0 DRIVE You may order one optional USB 2.0 drive. One socket on the motherboard can accommodate an 8 or 16 GB drive. The 8 or 16 GB drive (if ordered) is blank and comes installed on the motherboard. It can be used for a hypervisor or a license dongle. The USB drive ordering information is listed in Table 16. Table 16 USB 2.
CONFIGURING the SERVER STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE Several operating systems and value-added software programs are available. Select as desired from Table 17.
CONFIGURING the SERVER Table 17 OSs and Value-Added Software (for 2-CPU servers) (continued) PID Description Product ID (PID) Red Hat Enterprise Linux RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required RHEL-2S-1G-3A RHEL/2 Socket/1 Guest/3Yr Svcs Required RHEL-2S-4G-1A RHEL/2 Socket/4 Guest/1Yr Svcs Required RHEL-2S-4G-3A RHEL/2 Socket/4 Guest/3Yr Svcs Required RHEL-2S-UG-1A RHEL/2 Socket/U Guest/1Yr Svcs Required RHEL-2S-UG-3A RHEL/2 Socket/U Guest/3Yr Svcs Required RHEL-HA-2S-1A RHEL Op
CONFIGURING the SERVER Table 17 OSs and Value-Added Software (for 2-CPU servers) (continued) PID Description Product ID (PID) VMware 5 VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd VMW-VS5-STD-2A VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd VMW-VS5-STD-3A VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd VMW-VS5-STD-4A VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd VMW-VS5-STD-5A VMware vSphere 5 Standard for 1 Proces
CONFIGURING the SERVER STEP 14 SELECT OPERATING SYSTEM MEDIA KIT Select the optional operating system media listed in Table 18.
CONFIGURING the SERVER STEP 15 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available, as described in this section. Unified Computing Warranty, No Contract If you have noncritical implementations and choose to have no service contract, the following coverage is supplied: ■ Three-year parts coverage. ■ Next business day (NBD) onsite parts replacement eight hours a day, five days a week. ■ 90-day software warranty on media.
CONFIGURING the SERVER SMARTnet for UCS Hardware Only Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required.
CONFIGURING the SERVER See Table 21.
CONFIGURING the SERVER You can choose a service listed in Table 23.
CONFIGURING the SERVER Table 24 Drive Retention Service Options (continued) Service Description Service Program Name SMARTnet for UCS HW ONLY+Drive Retention UCS HW+DR Service Level GSP Service Level Product ID (PID) UCWD7 24x7x4 Onsite CON-UCWD7-C22M3S UCWD5 8x5xNBD Onsite CON-UCWD5-C22M3S For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.
OPTIONAL STEP - ORDER RACK(s) OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including the C22 M3 SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in Table 25. Racks are shipped separately from the C22 M3 SFF server.
OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC22 M3 server. This PDU is available in a zero rack unit (RU) style (see Table 25). Table 26 PDU Options Product ID (PID) PID Description RP208-30-2P-U-2 Zero RU PDU For more information about the PDU, see PDUs, page 59.
SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C22 M3 chassis with the top cover removed is shown in Figure 6.
SUPPLEMENTAL MATERIAL 5 DIMM slots on motherboard (12) 13 Integrated SAS RAID connectors on motherboard (left to right, SCU_Port 0, SCU_Port 1) 6 CPU and heatsinks (2) 14 Software RAID 5 key header on motherboard 7 PCIe riser 1 (PCIe slot 1) 15 RAID SCU option ROM header on motherboard 8 Internal USB 2.
SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks A1 A2 B1 B2 C1 C2 CPU1 Front of Server D1 D2 E1 E2 F1 F2 285209 CPU2 50 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server, you should consider the following items: ■ ■ Each channel has two DIMM slots (for example, channel A = slots A1 and A2). — Each channel can operate with one or two DIMMs installed. — If a channel has only one DIMM, populate slot 1 first (the blue slot). When both CPUs are installed, populate the DIMM slots of each CPU identically.
SUPPLEMENTAL MATERIAL Recommended Memory Population This section explains the recommended DIMM population order rules for the C22 M3 server. ■ All DIMMs must be DDR3 DIMMs. ■ Mixing of Registered and Unbuffered DIMMs is not allowed per platform. ■ Do not mix 1333-MHz DIMMs with 1600-MHz DIMMs. Follow Table 27 when populating DIMMs in the server.
SUPPLEMENTAL MATERIAL Additional DIMM Populations The list in Table 28 is not a complete list of all supported DIMM populations, but highlights common configuration options.
SUPPLEMENTAL MATERIAL Low-Voltage DIMM Considerations The C22 M3 server can be ordered with low-voltage (1.35 V) DIMMs only. Note the following considerations: 54 ■ Low-voltage DIMMs within the server must have the identical manufacturer, type, speed, and size. ■ Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that this causes the system BIOS to default to standard-voltage operation (Performance Mode).
SUPPLEMENTAL MATERIAL RAID Summary ■ ROM5 and ROM55 embedded RAID upgrade options each support up to 8 drives. ■ The LSI MegaRAID SAS 9270CV-8i, 9240-8i, and 9220-8i RAID controller cards each support up to 8 drives NOTE: If you do not select a PCIe RAID controller or one of the embedded RAID upgrade options (ROM5 or ROM55), you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10).
SUPPLEMENTAL MATERIAL RAID Option ROM (OPROM) Settings The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS screen is shown in Figure 8.
SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 9) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: ■ Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in Table 30. Table 30 Cisco R42610 Rack Specifications Parameter Standard Rack Expansion Rack Dimensions (H x W x D) 78.
SUPPLEMENTAL MATERIAL Figure 9 Cisco R42610 Rack Front view - door closed 58 Front view - door open Front view - door removed Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician. With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.
SUPPLEMENTAL MATERIAL Motherboard USB Port The C22 M3 SFF motherboard has one general-purpose USB socket as shown in Figure 11. Figure 11 Motherboard USB Port SYS FAN1 CPU 1 SYS FAN2 PCIe 1 1 SYS FAN3 SYS FAN4 PCIe 2 CPU 2 SYS FAN5 PSU 1 1 Internal USB 2.
SUPPLEMENTAL MATERIAL LED Indicators The server contains LED indicators on the front and rear panels. Their functions are described in the following sections. Front Panel Figure 12 shows the front panel LEDs.
SUPPLEMENTAL MATERIAL Table 31 Front Panel LEDs (continued) LED LED State Meaning System Status Off Undefined On (green) Server is in normal operating condition On (amber) Server is in a degraded operational state. For example: Blinking (amber) Fan Status Temperature Status Power Supply Status Network Link Status 62 ■ Power supply redundancy is lost. ■ CPUs are mismatched. ■ At least one CPU is faulty. ■ At least one DIMM is faulty.
SUPPLEMENTAL MATERIAL Table 31 Front Panel LEDs (continued) LED Hard Drive Fault Hard Drive Activity LED State Meaning Blinking (green) Activity on any of the LOM ports Off The hard drive is operating properly On (amber) The hard drive has failed Blinking (amber) The hard drive is rebuilding Off There is no hard drive in the hard drive sled (no access, no fault) On (green) The hard drive is ready Blinking (green) The hard drive is reading or writing data Rear Panel Figure 13 shows the re
SUPPLEMENTAL MATERIAL See Table 32 for the functions of the rear panel LEDs. Table 32 Rear Panel LEDs LED LED State Meaning Power Supply Fault Off The power supply is operating normally Blinking (amber) An event warning threshold has been reached, but the power supply continues to operate On (amber) A critical fault threshold has been reached, causing the power supply to shut down (for example, a fan failure or an over-temperature condition).
TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 33 UCS C22 M3 Dimensions and Weight Parameter Value Height 1.70 in (43.2 mm) Width 16.93 in.(430 mm) Depth 26.0 in. (660.4 mm) Front Clearance 3 in. (76 mm) Side Clearance 1 in. (25 mm) Rear Clearance 9 in. (233 mm) Weight Maximum (8 HDDs, 2 CPUs, 12 DIMMs, 1 power supply) 27.78 lbs (12.6 kg) Bare (0 HDD, 0 CPU, 0 DIMM, no power supply) 23.48 lbs (10.
TECHNICAL SPECIFICATIONS NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. The general power specifications for the C22 M3 SFF server 650 W power supply are listed in Table 34. Table 35 UCS C22 M3 SFF 650 W Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self-ranging, 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal) Maximum AC input current 7.6 A maximum at 100 VAC 3.
TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C22 M3 server are listed in Table 36. Table 36 UCS C22 M3 Environmental Specifications Parameter Minimum Temperature operating 41 to 95° F (5 to 35° C) Maximum temperature is to be derated by 1 degree C for every 305 m (1000 ft.) of altitude above sea level Temperature nonoperating –40 to 149°F (–40 to 65°C) Humidity (RH) nonoperating, non-condensing 10 to 90% Altitude operating 0 to 3,000 m (0 to 10,000 ft.
TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory compliance requirements for C-Series servers are listed in Table 37. Table 37 UCS C-Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC Safety UL 60950-1 Second Edition CAN/CSA-C22.2 No.