Spec Sheet Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV D.
CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 BASE SERVER STANDARD CAPABILITIES and FEATURES . .
KVM CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Motherboard USB and SD Ports, and RAID Card Backup Locations . . . . . . . . . . . . . . . . . . . 84 TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . Environmental Specifications . . . . . . . . . . . .
CONTENTS 4 Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
OVERVIEW OVERVIEW The UCS C240 M3 rack server is designed for both performance and expandability over a wide range of storage-intensive infrastructure workloads from big data to collaboration. The enterprise-class UCS C240 M3 server extends the capabilities of Cisco’s Unified Computing System portfolio in a 2U form factor with the addition of the Intel® Xeon E5-2600 v2 and E5-2600 series processor family CPUs that deliver the best combination of performance, flexibility and efficiency gains.
DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C240 M3 High-Density SFF Rack Server.
DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel. Figure 3 Chassis Rear View 1 2 3 PCIe 1 PCIe 5 PCIe 2 PCIe 4 PCIe 3 PSU2 4 5 6 7 8 9 10 11 1 Power supplies (up to two) 7 One RJ-45 10/100/1000 Ethernet dedicated management port 2 Standard-profile PCIe slot on riser 2: 8 USB 2.0 port 9 Quad 1-GbE ports 331826 PSU1 PCIe 5—full-height, 3/4-length (approximately 10.5 in.
BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER, page 11.
BASE SERVER STANDARD CAPABILITIES and FEATURES Capability/Feature Storage controller Description ■ Embedded RAID (3 Gbs) • Embedded SATA-only RAID controller, supporting up to four SATA-only drives (RAID 0, 1, 10), or • ROM5 RAID upgrade, supporting up to eight SAS+SATA HDDs or SSDs (RAID 0, 1, 10), or • ROM55 RAID upgrade, supporting up to eight SAS+SATA HDDs or SSDs (RAID 0, 1, 5, 10).
BASE SERVER STANDARD CAPABILITIES and FEATURES Capability/Feature Video Interfaces Description The Emulex Pilot 3 Integrated Baseboard Management Controller provides video: ■ Matrox G200e video controller ■ Integrated 2D graphics core with hardware acceleration ■ Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at 60 Hz ■ 24-bit color depth for all resolutions less than 1600x1200 ■ 256 MB video memory Rear panel ■ One RJ-45 10/100/1000 Ethernet management port, using Cisc
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C240 M3 High-Density SFF Rack Server: ■ STEP 1 VERIFY SERVER SKU, page 12 ■ STEP 2 SELECT CPU(s), page 13 ■ STEP 3 SELECT MEMORY, page 16 ■ STEP 4 SELECT RAID CONFIGURATION, page 22 ■ STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 31 ■ STEP 6 SELECT PCIe OPTION CARD(s), page 33 ■ STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 36 ■ STEP 8 ORDER GPU CARDS and ACCESSORIES
CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Select one server product ID (PID) from Table 2.
CONFIGURING the SERVER STEP 2 SELECT CPU(s) The standard CPU features are: ■ Intel Xeon E5-2600 v2 and E5-2600 series processor family CPUs (see the following link for instructions on how to upgrade your server from Intel Xeon E5-2600 to Intel Xeon E5-2600 v2 CPUs: http://preview.cisco.com/en/US/docs/unified_computing/ucs/c/CPU/IVB/install/IVB-C.html ■ Intel® C600 series chipset ■ Cache sizes of up to 30 MB Select CPUs The available CPUs are listed in Table 3.
CONFIGURING the SERVER Table 3 Available Intel CPUs: Intel Xeon E5-2600 v2 and E5-2600 series processor family CPUs Intel Number Clock Freq (GHz) Power (W) Cache Size (MB) Cores QPI Highest DDR3 DIMM Clock Support (MHz)1 UCS-CPU-E5-2690 E5-2690 2.90 135 20 8 8 GT/s 1600 UCS-CPU-E5-2680 E5-2680 2.70 130 20 8 8 GT/s 1600 UCS-CPU-E5-2670 E5-2670 2.60 115 20 8 8 GT/s 1600 UCS-CPU-E5-2667 E5-2667 2.90 130 15 6 8 GT/s 1600 UCS-CPU-E5-2665 E5-2665 2.
CONFIGURING the SERVER Approved Configurations (1) 1-CPU configurations: ■ Select any one CPU listed in Table 3. (2) 2-CPU Configurations: ■ Select two identical CPUs from any one of the rows of Table 3 on page 13. Caveats ■ You can select either one processor or two identical processors. ■ For optimal performance, select DIMMs with the highest clock speed for a given processor (see Table 3 on page 13).
CONFIGURING the SERVER STEP 3 SELECT MEMORY The standard memory features are: ■ ■ Figure 4 16 DIMMs — Clock speed: 1866, 1600, or 1333 MHz — Ranks per DIMM: 1, 2, or 4 — Operational voltage: 1.5 V or 1.35 V — Registered or unbuffered ECC DDR3 DIMMs (RDIMMs or UDIMMs) or load-reduced DIMMs (LRDIMMs) Memory is organized with four memory channels per CPU, with up to three DIMMs per channel, as shown in Figure 4.
CONFIGURING the SERVER Select DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mirroring option are listed in Table 4. NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel.
CONFIGURING the SERVER ■ Select from 1 to 12 DIMMs. Refer to Memory Population Rules, page 66, for more detailed information. (2) 1-CPU configuration with memory mirroring: ■ Select 2, 4, 6, 8, or 12 identical DIMMs. The DIMMs will be placed by the factory as shown in the following table.
CONFIGURING the SERVER (4) 2-CPU configuration with memory mirroring: ■ Select 2, 4, 6, 8, or 12 identical DIMMs per CPU. The DIMMs will be placed by the factory as shown in the following table.
CONFIGURING the SERVER Caveats ■ System speed is dependent on how many DIMMs are populated per channel. See Table 5 for details. Table 5 DIMM Memory Speeds 1333-MHz Capable CPU DIMM Speed 1333 DIMM 1600 DIMM 1866 DIMM3 1600-MHz Capable CPU 1866-MHz Capable CPU LRDIMM RDIMM (DR, SR) LRDIMM RDIMM (DR, SR) LRDIMM RDIMM (DR, SR) Voltages Voltages Voltages Voltages Voltages Voltages DPC 1.3 V 1.5 V 1.3 V 1.5 V 1.3 V 1.5 V 1.
CONFIGURING the SERVER — DIMM population (how many DIMMs per channel are populated) — BIOS setting. For the DIMMs to run in power-savings mode (1.35 V, if the DIMM supports this), change the BIOS setting to power-savings mode. ■ With 3 RDIMMs populated per channel, memory always runs at 1.5 V regardless if the BIOS setting is power-savings mode (1.35 V) or performance mode (1.5 V). ■ With 3 LRDIMMs populated per channel, memory can operate at 1.5 V or 1.35 V, depending on the BIOS setting.
CONFIGURING the SERVER STEP 4 SELECT RAID CONFIGURATION NOTE: For the UCSC-C240-M3S2 (16-drive server), if you do not select a mezzanine card, a PCIe RAID controller, or one of the embedded RAID upgrade options, you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10) NOTE: The UCSC-C240-M3S (24-drive server) does not support embedded RAID, which is normally installed on the motherboard and does not consume a PCIe slot.
CONFIGURING the SERVER Select RAID Options Select as follows (these choices are dependent on the number of CPUs installed and the backplane used (24-drive or 16-drive backplane)): ■ One embedded RAID upgrade option for internal drives, or ■ One mezzanine RAID controller for internal drives, or ■ One mezzanine RAID controller for internal drives and one RAID controller for external drives, or ■ One RAID controller for internal drives, or ■ One RAID controller for internal drives and one RAID contro
CONFIGURING the SERVER Table 7 Available Mezzanine Card RAID Options (continued) Product ID (PID) PID Description UCSC-RAID-11-C240 Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 5, 10, and 50 supported), operating at 6 Gbs. UCSC-RAID-MZ-240 ■ Supports up to 8 internal SAS+SATA drives with the 16-drive system or up to 16 internal SAS+SATA drives with the 24-drive system. SAS and SATA drives can be mixed.
CONFIGURING the SERVER Table 8 Available PCIe RAID Controller Options (continued) Product ID (PID) PID Description UCS-RAID-9285CV-E or LSI MegaRAID SAS 9285CV-8e or 9286CV-8e (RAID 0, 1, 5, 6, 10) UCS-RAID9286CV-8E ■ Supports eight external SAS ports (up to 240 external drives). NOTE: For SAS 9285CV-8e or 9286CV-8e external drive enclosure support, see the compatibility list (enclosure section) at the following link: http://tinyurl.
CONFIGURING the SERVER Table 8 Available PCIe RAID Controller Options (continued) Product ID (PID) PID Description Supercapacitor Option UCS-RAID-CV-SC= LSI CacheVault Power Module. This is a spare supercapacitor. It is the exact same supercapacitor that ships with the 9271CV-8i, 9285CV-8e, and 9286CV-8e cards listed earlier in this table and can be used as a replacement or upgrade part.
CONFIGURING the SERVER Approved Configurations The C240 M3 SFF server can be ordered as a UCSC-C240-M3S2 (16-drive backplane with no SAS expander) or a UCSC-C240-M3S (24-drive backplane with SAS expander). ■ ROM5 and ROM 55 embedded RAID upgrade options support up to 8 internal drives with the 16-drive backplane and are not supported for the 24-drive backplane.
CONFIGURING the SERVER Table 9 Supported RAID Configurations Server # Embedded CPUs RAID1 Mezz RAID2 NYTRO Internal MegaRAID PCIe RAID 200 RAID #13 Card Internal PCIe RAID #2 External PCIe RAID4 # Drives Supported PCIe Slots5 12345 C240 M3 SFF 24 HDD 1 Not allowed Not allowed6 Not allowed Installed slot 3 (default)7 Not allowed C240 M3 SFF 24 HDD 1 Not allowed Not allowed Not allowed Not allowed Not allowed C240 M3 SFF 24 HDD 2 Not allowed Installed Not allowed Not allowed Not
CONFIGURING the SERVER Table 9 Supported RAID Configurations Server # Embedded CPUs RAID1 Mezz RAID2 NYTRO Internal MegaRAID PCIe RAID 200 RAID #13 Card Internal PCIe RAID #2 External PCIe RAID4 # Drives Supported PCIe Slots5 12345 C240 M3 SFF 16 HDD 2 Not allowed Installed Not allowed Not allowed Not allowed Card absent 8 internal A A A A A C240 M3 SFF 16 HDD 2 Not allowed Not allowed Not allowed Installed slot 4 (default) Card absent Card absent 8 internal A A A O A C240 M3 SFF
CONFIGURING the SERVER ROM (OPROM) setting to enable a different slot for an internal drive RAID controller. Any remaining slot can then be used for an external drive RAID controller or for a PCIe expansion card. ■ Note that when just one CPU is populated, only a single Cisco 1225 Virtual Interface Card (VIC) card is supported and it must be installed in the full-height PCIe slot (slot 2) on riser 1. So take this into account when populating RAID controller cards.
CONFIGURING the SERVER STEP 5 (SSDs) SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES The standard disk drive features are: ■ 2.5-inch small form factor ■ Hot-pluggable ■ Sled-mounted Select Drives The available drives are listed in Table 10. Table 10 Available Hot-Pluggable Sled-Mounted HDDs and SSDs PID Description Drive Type Capacity A03-D1TBSATA 1 TB SATA 7.2K RPM SFF HDD SATA 1 TB UCS-HD1T7KS2-E 1TB SAS 7.2K RPM 2.
CONFIGURING the SERVER Approved Configurations (1) Onboard RAID, Mezzanine Cards, and all PCIe RAID Controllers ■ ■ For systems with a 16-drive backplane: — If you have not selected an onboard RAID upgrade option (ROM5 or ROM55), a mezzanine card, or a PCIe RAID controller for internal drives (LSI MegaRAID SAS 9271-8i or 9271CV-8i), you may select up to 4 SATA-only drives from Table 10. — Select up to 8 drives for ROM5 or ROM55 embedded RAID upgrade or a mezzanine card.
CONFIGURING the SERVER STEP 6 SELECT PCIe OPTION CARD(s) The standard PCie card offerings are: ■ Converged Network Adapters (CNAs) ■ Network Interface Cards (NICs) ■ Host Bus Adapters (HBAs) ■ UCS Storage Accelerators Select PCIe Option Cards The available PCIe option cards are listed in Table 11.
CONFIGURING the SERVER Table 11 Available PCIe Option Cards (continued) Product ID (PID) PID Description Card Height N2XX-AQPCI05 QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half UCSC-PCIE-Q2672 Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics Half UCSC-PCIE-E16002 Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics Half UCS Storage Accelerators UCSC-F-FIO-3000M Cisco UCS 3.
CONFIGURING the SERVER — ■ ■ ■ Fusion ioDrive2 cards can be installed in slots 1, 2, or 3. Note that the only the Cisco UCS 3.0 TB MLC Fusion ioDrive2 card is full-height; all other Fusion ioDrive2 cards are half-height and therefore may need an adapter to hold them securely in the available slots. For 2-CPU systems: — Five PCIe slots are available, three on PCIe riser 1 (PCIe slots 1, 2, and 3) and two on PCIe riser 2 (PCIe slots 4 and 5). — All of the slots are full-height except slot 4.
CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server. Choose Optional Twinax Cables Table 12 lists the copper twinax cables available for the PCIe cards. You can choose cable lengths of 1, 3, 5, 7, or 10 meters.
CONFIGURING the SERVER Approved Configurations (1) Choose Up to Two SFP+ Modules for Each Network Card Ordered ■ You may choose one or two SFP+ optical modules cables for each compatible PCIe network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available. See Figure 5 on page 39 for typical SFP+ and twinax connections to the network cards.
CONFIGURING the SERVER Table 14 PCIe Card Compatibility Cisco SFP Modules Twinax Cables SFP-10G-SR DS-SFP-FC8G-SW PCIe Cards Converged Network Adapters (CNAs) UCSC-PCIE-BSFP (Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI) UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) UCSC-PCIE-C10T-02 (Cisco VIC 1225T Dual Port 10GBaseT CNA) UCSC-PCIE-ESFP (Emulex OCe11102-FX dual-port 10 GbE FCoE CNA (Gen 3 CNA)) UCSC-PCIE-QSFP (QLogic QLE8242-CU dual-port 10 GbE FCoE CNA) UCSC-PCIE-B3SFP (Broadcom 57810 10G
CONFIGURING the SERVER Figure 5 Network Card Connections Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 39
CONFIGURING the SERVER STEP 8 ORDER GPU CARDS and ACCESSORIES (OPTIONAL) The GPU offerings are: ■ GPU upgrade kit ■ GPU PCIe cards ■ GPU power cables NOTE: The GPU cards and accessories are orderable for both the 16-drive and 24-drive backplane versions of the server. Select GPU Options The available GPU PCIe options are listed in Table 15.
CONFIGURING the SERVER Approved Configurations (1) GPU Kit ■ Select a GPU kit to prepare the C240 M3 chassis (V01 chassis version only) for GPU capability. If you have a newer V02 chassis, you do not need a GPU kit. (2) GPU Power Cables ■ When you order one or two GPUs for a V02 chassis version, you also need to order one or two power cables. Order the “Y” power cable (UCSC-GPUCBL-88Y=) for 2 GPUs and the “straight” power cable (UCSC-GPUCBL-88S=) for a single GPU.
CONFIGURING the SERVER CAUTION: When using dual NVIDIA Tesla GPU cards, you must preserve at least 10 mm of space between servers to ensure adequate airflow and cooling. CAUTION: When using NVIDIA Tesla GPU cards, the operating temperature range is 32° to 95°F (0° to 35°C). NOTE: Mixing different GPU cards in the same server is not supported. NOTE: All GPU cards require two CPUs and two 1200 W power supplies in the server.
CONFIGURING the SERVER Figure 6 Serial Number Label and Chassis Version ID PID VID: ||||||||||||||||||||||||||||||||| UCSC-C240-M3S V01 2 336574 1 1 PID/VID label on top of server 2 Version ID on label Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 43
CONFIGURING the SERVER STEP 9 ORDER POWER SUPPLY The C240 M3 server requires at least one power supply. A lightly loaded server may require one or two 650 W power supplies. A fully loaded server might need to be powered with two 1200 W power supplies. A server with one GPU requires at least one 1200 W power supply; a server with two GPUs requires two 1200 W power supplies.
CONFIGURING the SERVER STEP 10 SELECT AC POWER CORD(s) Using Table 19, select the appropriate AC power cords. You can select a minimum of no power cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
CONFIGURING the SERVER Table 19 Available Power Cords Product ID (PID) PID Description SFS-250V-10A-AR Power Cord, SFS, 250V, 10A, Argentina Images 2500 mm Cordset rating: 10 A, 250/500 V MAX Length: 8.
CONFIGURING the SERVER Table 19 Available Power Cords Product ID (PID) PID Description CAB-9K10A-IT Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy Images Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector C15M (EN60320/C15 ) 186575 Plug: I/3G (CEI 23-16) CAB-9K10A-SW Power Cord, 250VAC 10A MP232 Plug, Switzerland Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.
CONFIGURING the SERVER STEP 11 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use Table 20 to order a cable management arm.
CONFIGURING the SERVER STEP 12 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy.
CONFIGURING the SERVER STEP 13 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) You can order up to two optional preloaded 16 GB Cisco Flexible Flash secure digital (SD) cards. The first SD card contains preloaded software for simplified server operation. The ordering information is listed in Table 22. Table 22 Secure Digital (SD) Card (preloaded with software) Product ID (PID) PID Description UCSC-SD-16G-C240 16GB SD Card for C240 servers See Figure 7 on page 63 for the location of the SD cards.
CONFIGURING the SERVER STEP 14 ORDER OPTIONAL USB 2.0 DRIVE You can order one optional USB 2.0 drive. The USB drive ordering information is listed in Table 24. Table 24 USB 2.0 Drive Product ID (PID) PID Description UCS-USBFLSH-S-4GB 4GB Flash USB Drive (shorter length) for all servers except C260 See Figure 7 on page 63 for the location of the USB connector.
CONFIGURING the SERVER STEP 15 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE Several operating systems and value-added software programs are available. Select as desired from Table 25.
CONFIGURING the SERVER Table 25 OSs and Value-Added Software (for 2-CPU servers) (continued) PID Description Product ID (PID) Red Hat Enterprise Linux RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required RHEL-2S-1G-3A RHEL/2 Socket/1 Guest/3Yr Svcs Required RHEL-2S-4G-1A RHEL/2 Socket/4 Guest/1Yr Svcs Required RHEL-2S-4G-3A RHEL/2 Socket/4 Guest/3Yr Svcs Required RHEL-2S-UG-1A RHEL/2 Socket/U Guest/1Yr Svcs Required RHEL-2S-UG-3A RHEL/2 Socket/U Guest/3Yr Svcs Required RHEL-HA-2S-1A RHEL Op
CONFIGURING the SERVER Table 25 OSs and Value-Added Software (for 2-CPU servers) (continued) PID Description Product ID (PID) VMware 5 VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd VMW-VS5-STD-2A VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd VMW-VS5-STD-3A VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd VMW-VS5-STD-4A VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd VMW-VS5-STD-5A VMware vSphere 5 Standard for 1 Proces
CONFIGURING the SERVER STEP 16 SELECT OPERATING SYSTEM MEDIA KIT Select the optional operating system media listed in Table 26.
CONFIGURING the SERVER STEP 17 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available, as described in this section. Unified Computing Warranty, No Contract If you have noncritical implementations and choose to have no service contract, the following coverage is supplied: ■ Three-year parts coverage. ■ Next business day (NBD) onsite parts replacement eight hours a day, five days a week. ■ 90-day software warranty on media.
CONFIGURING the SERVER SMARTnet for UCS Hardware Only Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required.
CONFIGURING the SERVER Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support. See Table 29.
CONFIGURING the SERVER You can choose a service listed in Table 31.
CONFIGURING the SERVER Table 32 Drive Retention Service Options Service Description Service Program Name SMARTnet for UCS Service with Drive Retention UCS DR SMARTnet for UCS HW ONLY+Drive Retention UCS HW+DR Service Level GSP Service Level Product ID (PID) UCSD7 24x7x4 Onsite CON-UCSD7-C240M3SF UCSD7 8x5xNBD Onsite CON-UCSD5-C240M3SF UCWD7 24x7x4 Onsite CON-UCWD7-C240M3SF UCWD5 8x5xNBD Onsite CON-UCWD5-C240M3SF For more service and support information, see the following URL: http://ww
OPTIONAL STEP - ORDER RACK(s) OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including the C240 M3 SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in Table 33. Racks are shipped separately from the C240 M3 SFF server.
OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC240 M3 server. This PDU is available in a zero rack unit (RU) style (see Table 33). Table 34 PDU Options Product ID (PID) PID Description RP208-30-2P-U-2 Zero RU PDU For more information about the PDU, see PDUs, page 82.
SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C240 M3 chassis with the top cover removed is shown in Figure 7.
SUPPLEMENTAL MATERIAL 8 SCU upgrade ROM header 18 Power supplies (two, hot-swappable access through rear panel) 9 Integrated RAID on motherboard, and mini-SAS connectors 19 Supercap RAID data cache power backup unit mounting locations (two, on air baffle not shown in this view) 10 Software RAID key header 20 GPU-ready power connector CPUs and DIMMs Physical Layout Each CPU has four DIMM channels: ■ CPU1 has channels A, B, C, and D ■ CPU2 has channels E, F, G, and H Each DIMM channel has thr
SUPPLEMENTAL MATERIAL Figure 8 Physical Layout of CPU DIMM Channels and Banks C1 C2 C3 D1 D2 D3 CPU 1 Front of Server B3 B2 B1 A3 A2 A1 G1 G2 G3 H1 H2 H3 F3 F2 F1 E3 E2 E1 331840 CPU 2 Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 65
SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server, you should take into account the following: ■ ■ Each channel has three DIMM slots (for example, channel A = slots A1, A2, and A3). — A channel can operate with one, two, or three DIMMs installed. — If a channel has only one DIMM, populate slot 1 first (the blue slot). When both CPUs are installed, populate the DIMM slots of each CPU identically.
SUPPLEMENTAL MATERIAL DIMM Population Order Populate the DIMMs for a CPU according to Table 36.
SUPPLEMENTAL MATERIAL Recommended Memory Configuration This section explains the recommended DIMM population order rules for the C240 M3 server. ■ All DIMMs must be DDR3 DIMMs. ■ Do not mix: — DIMMs with different sizes or clock rates in a channel — RDIMMs and LRDIMMs — ECC and non-ECC DIMMs ■ There are blue and black DIMM slots. Populate blue slots first.
SUPPLEMENTAL MATERIAL Table 37 Recommended Memory Configurations1 (continued) CPU 1 DIMMs Total System Memory Size Blue Slots Bank 1 (A1,B1, C1,D1) CPU 2 DIMMs Black Slots Black Slots Blue Slots Black Slots Black Slots Bank 2 Bank 3 Bank 1 Bank 2 Bank 3 (A2,B2, (A3,B3, (E1,F1, (E2,F2, (E3,F3, C2,D2) C3,D3) G1,H1) G2,H2) G3,H3) DIMM Max Speed (MHz) Total DIMMs 256 GB 4x16 GB 4x16 GB — 4x16 GB 4x16 GB — 1600 16 384 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 1333 24 512 GB 4x3
SUPPLEMENTAL MATERIAL Supported DIMM Populations The supported DIMM populations are listed in Table 38.
SUPPLEMENTAL MATERIAL Table 38 Supported DIMM Configurations (continued) Total DIMMs for CPU 1 CPU 1 DIMMs CPU 1 CPU 2 DIMMs Capacity Total DIMMs for CPU 2 Total CPU 2 Capacity for Capacity 2 CPUs 11 x 8 GB 11 88 GB 11 x 8 GB 11 88 GB 176 GB 6 x 16 GB 6 96 GB 6 x 16 GB 6 96 GB 192 GB 4x8GB + 4x16GB 8 96 GB 4x8GB + 4x16GB 8 96 GB 192 GB 12 x 8 GB 12 96 GB 12 x 8 GB 12 96 GB 192 GB 3 x 32 GB 3 96 GB 3 x 32 GB 3 96 GB 192 GB 7 x 16 GB 7 112 GB 7 x 16 GB 7 112 GB 2
SUPPLEMENTAL MATERIAL RAID Details The available RAID configurations are shown in this section. (1) 1-CPU Configurations ■ For a 24-drive backplane system, select one of the following: — One internal drive RAID controller from Table 8 on page 24 — One external drive RAID controller from Table 8 on page 24 You may also select an appropriate optional RAID configuration listed in Table 8 on page 24.
SUPPLEMENTAL MATERIAL — Two internal drive RAID controllers from Table 8 on page 24 — One external drive RAID controller from Table 8 on page 24 — One mezzanine RAID controller from Table 7 on page 23 and one external PCIe RAID controller from Table 7 on page 23 — One internal drive RAID controller from Table 7 on page 23 and one external drive PCIe RAID controller from Table 7 on page 23 You may also select an appropriate optional RAID configuration listed in Table 8 on page 24.
SUPPLEMENTAL MATERIAL RAID Option ROM (OPROM) Settings The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS screen is shown in Figure 9.
SUPPLEMENTAL MATERIAL Serial Port Details The pinout details of the rear RJ-45 serial port connector are shown in Figure 10.
SUPPLEMENTAL MATERIAL Upgrade and Servicing-Related Parts This section lists the upgrade and servicing-related parts you may need during the life of your server. Some of these parts are configured with every server, and some may be ordered when needed or may be ordered and kept on hand as spares for future use. See Table 39. Table 39 Upgrade and Servicing-related Parts for UCS C240 M3 SFF Server Spare Product ID (PID) Description N20-BBLKD= 2.
SUPPLEMENTAL MATERIAL Table 39 Upgrade and Servicing-related Parts for UCS C240 M3 SFF Server Spare Product ID (PID) Description UCSX-HSCK= UCS Processor Heat Sink Cleaning Kit (when replacing a CPU)8 Notes . . . 1. This part is included/configured with your UCS server (in some cases, as determined by the configuration of your server). 2.
SUPPLEMENTAL MATERIAL CPU Removal and Installation (“pick n place”) Tool Set The Pick n Place tool set includes two tools: ■ Pick and pull cap tool - used to pull off the plastic protective cap covering an empty CPU socket and to remove or lift a CPU processor without touching it Pick and place tool - used to install a CPU in its socket without damage. Must be used each time a CPU is installed in a UCS “M3” server. ■ Instructions for using this tool set are found at the following link: http://www.cisco.
SUPPLEMENTAL MATERIAL CPU Heat Sink Cleaning Kit The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process. Instructions for cleaning are found at the following link: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C240/install/replace.html#wp1233864 NOTE: When you purchase a spare CPU, the CPU cleaning kit is included.
SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 11) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: ■ Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in Table 40. Table 40 Cisco R42610 Rack Specifications Parameter Standard Rack Expansion Rack Dimensions (H x W x D) 78.
SUPPLEMENTAL MATERIAL Figure 11 Cisco R42610 Rack Front view - door closed Front view - door open Front view - door removed Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 81
SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician. With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.
SUPPLEMENTAL MATERIAL KVM CABLE The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB 2.0 ports for a keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server. The KVM cable ordering information is listed in Table 41.
SUPPLEMENTAL MATERIAL Motherboard USB and SD Ports, and RAID Card Backup Locations The C240 M3 SFF motherboard has a general-purpose USB socket and two SD sockets, as shown in Figure 14.
TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 42 UCS C240 M3 Dimensions and Weight Parameter Value Height 3.43 in. (8.70 cm) Width (including slam latches) 17.54 in.(44.55 cm) Depth 28.04 in. (71.23 cm) Front Clearance 3 in. (76 mm) Side Clearance 1 in. (25 mm) Rear Clearance 6 in. (152 mm) Weight1 Maximum (8 HDDs, 2 CPUs, 24 DIMMs, 2 power supplies) 60 lbs (27.2 kg) Minimum (1 HDD, 1 CPU, 1 DIMM, 1 power supply) 38.4 lbs (17.
TECHNICAL SPECIFICATIONS Table 43 UCS C240 M3 SFF Power Specifications 650 W AC power supply) Description Specification AC input voltage range 90 to 264 VAC (self-ranging, 180 to 264 VAC nominal) AC input frequency Range: 47 to 63 Hz (single phase, 50 to 60Hz nominal) Maximum AC inrush current 11 A Maximum AC input current 7.6 A peak at 100 VAC 3.
TECHNICAL SPECIFICATIONS Table 45 UCS C240 M3 SFF Power Specifications 930 W DC power supply) Description Class Specification ■ RSP1 DC input voltage range ■ 40 to 72 VDC (self-ranging, 48 to 60 VDC nominal) DC line input current (steady state) ■ 23 A peak at 48 VDC 12 V main power output ■ 930 W 12 V standby power output ■ 30 W Power supply output voltage ■ Main power: 12 VDC ■ Standby power: 12 VDC ■ 2.
TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C240 M3 server are listed in Table 46. Table 46 UCS C240 M3 Environmental Specifications Parameter Minimum Temperature operating 41 to 104° F (5 to 40° C) derate the maximum temperature by 1°C per every 305 m of altitude above sea level Temperature nonoperating –40 to 149°F (–40 to 65°C) Humidity (RH) operating, non-condensing 10 to 90% Altitude operating 0 to 3,000 m (0 to 10,000 ft.
TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory compliance requirements for C-Series servers are listed in Table 47. Table 47 UCS C-Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC Safety UL 60950-1 Second Edition CAN/CSA-C22.2 No.
TECHNICAL SPECIFICATIONS Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 90