Release Notes for Catalyst5000 Family Software Release4.x
OL-2306-01
Open and Resolved Caveats in Software Release 4.5(5)
Resolved Caveats in Software Release4.5(5)
Note For a description of open caveats in software release4.5(5), see the “Open Caveats in Software
Release4.5(6)” section on page31.
This section describes caveats resolved in software release 4.5(5):
• If a switch is configured with the sc0 interface in a Token Ring VLAN, and there are parallel trunks
to another switch, it is possible for the first switch to erroneously detect a duplicate IP address. This
can lead to excessive console messages being displayed, making the console unusable.
Workaround: Move the sc0 interface into an Ethernet VLAN. (CSCdm93084)
• When the backup concentrator relay function (CRF) is configured on the Catalyst 5000 supervisor
engine, it is stored in the NVRAM, but when you enter a copy config command, the CRF
configuration parameters do not get copied with the rest of the switch configuration. If the switch is
power-cycled, the backup CRF configuration is retained in the NVRAM. (CSCdp38648)
• When a VTP client and a VTP server in a VTP domain are separated from each other by a VTP
transparent mode switch that is not a member of any VTP domain and the client is reset, the client
does not update its configuration after receiving a VTP update from the VTP server. This problem
is fixed in software release 4.5(5). (CSCdp05027)
• Telnet sessions to the switch are not released properly. This problem is fixed in software release
4.5(5). (CSCdp15609)
• If a switch is configured with the sc0 interface in a Token Ring VLAN and there are parallel trunks
to another switch, the first switch might erroneously detect a duplicate IP address. This can lead to
excessive console messages being displayed making the console unusable.
Workaround: Move the sc0 interface into an Ethernet VLAN. This problem is fixed in software
release 4.5(5). (CSCdm93084)
• Use of the set standbyports enable command to enable a port on a backup Supervisor Engine III
associates an ifIndex number with the port, which can be displayed by the show port command, but
the MIB object cdpInterfaceEntry does not see this ifIndex number. This causes CiscoWorks2000
map discovery to fail. To avoid this problem, reset the standby supervisor engine. This problem is
fixed in software release 4.5(5). (CSCdm30287)
• Communication using SLIP on the console port of a Supervisor EngineII might fail. This problem
is fixed in software release 4.5(5). (CSCdm45445)
• Multicast and broadcast traffic is not cleared correctly from the counters when the clear counter
command is issued. This problem is fixed in software release 4.5(5). (CSCdm94354)
• VTP Clients do not learn new configurations from each other.When the update timer in one VTP
client times out, it has to send a request advertisement but this request does not reach other clients
and the requesting client remains stuck waiting for the rest of the configuration. Resetting the switch
or changing the state of the switch enables the hung client to learn the configuration. This problem
is fixed in software release 4.5(5). (CSCdm90300)
• Cut-and-paste does not work with the session command for the WS-X5167 OC-3 ATM module.
This problem is fixed in software release 4.5(5). (CSCdp18016)