Datasheet
Data Sheet
© 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 19 of 23
Interface Type Name Max Distance Cable Type Part Number
10GBASE-LX4 10GBASE-LX4 X2
transceiver module for
MMF, 1310-nm
wavelength, SC duplex
connector
300m MMF X2: X2-10GB-LX4
10GBASE-LRM 10GBASE-LX4 X2
transceiver module for
MMF, 1310-nm
wavelength, SC duplex
connector
220m MMF X2-10GB-LRM
10GBASE-ZR 10GBASE-ZR X2
transceiver module for
SMF, 1550 nm
wavelength. DOM is
not supported.
80km SMF X2-10GB-ZR
10GBASE-DWDM 10GBASE-ZR X2
transceiver module for
SMF, 32 nontunable
ITU 100-GHz
wavelengths. DOM is
supported. Dual SC/PC
connectors are
supported.
80km SMF X2-10GB-DWDM
X2 to SFP converter TwinGig Converter
Module
CVR-X2-SFP
X2 to SFP converter
(10G)
10G X2 to SFP+
Converter
CVR-X2-SFP10G
Table 4. GBIC, SFP Options
Interface Type Name Max Distance Cable Type Part Number
1000BASE-T Category 5 twisted
pair
100m Category 5
●
SFP: GLC-T
●
GBIC: WS-G5483
1000BASE-SX Short wavelength 550m MMF
●
SFP: GLC-SX-MM
●
GBIC: WS-G5484
1000BASE-LX Long
wavelength/long haul
10 km on SMF
5 km on MMF
SMF
●
SFP: GLC-LH-SM
●
GBIC: WS-G5486
1000BASE-ZX Extended distance 70 km to 100 km SMF
●
SFP: GLC-ZX-SM
●
GBIC: WS-G5487
CWDM Coarse wavelength-
division multiplexing
100 km SMF
●
SFP: CWDM-SFP-XXXX
●
GBIC: CWDM-GBIC-XXXX
DWDM Dense wavelength-
division multiplexing
– – GBIC only
Table 5. Fast Ethernet Optical Transmission Characteristics
Launch Power
Port Type BER
Nominal Wavelength
(NM)
Max (dBm) Min (dBm)
100BASE-FX 2.5 x 10e-(10) 1270–1380 –14 –20
100BASE-LX10* 1 x 10e-(12) 1260–1360 –8 –15
100BASE-BX10-D3** 1 x 10e-(12) 1480–1580 –8 –14
* Draft 1.3.
** Draft 2.0.