Datasheet

2-3
Catalyst 6500 Series Ethernet Modules Installation Guide
OL-6265-02
Chapter 2 Ethernet Switching Modules
10 and 10/100 Fiber-Based Ethernet Modules
Digital Optical Monitoring
(DOM) support
Not supported
Module front panel LEDs STATUS
Green—All diagnostics pass; the module is operational.
Orange—The module is booting or running diagnostics; an
overtemperature condition has occurred.
LINK
Green—The port is active (the link is connected and operational).
Flashing orange—The port failed diagnostics and is disabled.
Orange—The port is disabled.
Red—The module is resetting; an overtemperature condition has
occurred.
Note If the module fails to download code and configuration
information successfully during the initial reset, the LED stays
red; the module does not come online.
Off—The port is not active or the link is not connected.
Table 2-2 WS-X6024-10FL-MT Ethernet Module Physical and Environmental Specifications
Item Specification
Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis.
Weight 7.0 lb (3.18 kg)
Power requirement
(at 42 VDC)
1.52 A
Environment
Operating temperature
Certified for operation: 32° to 104°F ( to 40°C)
Designed and tested for operation: 32° to 13F (0° to 55°C)
Humidity (RH) ambient
(noncondensing)
10 to 90%
Operating altitude
Certified for operation: 0 to 6500 ft (0 to 2000 m)
Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
Table 2-1 WS-X6024-10FL-MT Ethernet Module Features (continued)
Feature Description