Datasheet

2-39
Catalyst 6500 Series Ethernet Modules Installation Guide
OL-6265-02
Chapter 2 Ethernet Switching Modules
10/100 and 10/100/1000 Ethernet Modules
Module upgrades available
PoE support WS-X6548-GE-TX—Field-upgradeable to Cisco prestandard only by
installing the WS-F6K-VPWR-GE= daughter card or both Cisco
prestandard and IEEE 802.3af by installing the WS-F6K-GE48-AF=
daughter card.
Note Refer to the Cisco Catalyst 6500 Series Power over Ethernet
Daughter Cards Field-Upgrade Installation Note for field
upgrade procedures.
Distributed forwarding
support
Not supported.
Pluggable transceivers
support
Not supported.
TDR support All module variants support TDR.
Module front panel LEDs STATUS
Green—All diagnostics pass; the module is operational.
Orange—The module is booting or running diagnostics.
An overtemperature condition has occurred. (A minor temperature
threshold has been exceeded during environmental monitoring.)
Red—The module is resetting. The switch has just been powered
on or the module has been hot inserted during the normal
initialization sequence.
An overtemperature condition has occurred. (A major temperature
threshold has been exceeded during environmental monitoring.)
If the module fails to download code and configuration information
successfully during the initial reset, the LED stays red; the module
does not come online.
LINK
Green—The port is active (the link is connected and operational).
Orange—The module or port is disabled through the CLI command
or the module is initializing
1
.
Flashing orange—The port is faulty and has been disabled.
Off—The port is not active or the link is not connected.
PHONE
Green—The PoE daughter card is installed and detected.
Off—The PoE daughter card is not detected or is not installed.
1. Verify that all LINK LEDs are functioning.
Table 2-32 WS-X6548-GE-TX Modules Features (continued)
Feature Description