JUNGLE MIST JUNIOR ANTI-DRIPTM Operating Instructions 110VAC P/N 100072 12VDC P/N 100068 230VAC P/N 100074 (w/transformer)
! ! ! ! Thank you for purchasing this Jungle Mist Junior Anti-DripTM As you will notice from the table of contents, the manual for your new pump is quite extensive. To guarantee perfect and successful work with this machine, please take time to read the manual carefully. Do not operate before changing oil cap! And finally, we believe you will enjoy many years of dependable, trouble free service if you properly install and maintain your Jungle Mist Junior Anti-DripTM CITC 2100 196th St. S.W., Ste.
Contents 1. Equipment Supplied 3 2. Accessories and Parts 3 3. Safety information 4 4. Grounding Instructions 4 5. Receiving and Unpacking 5 5.1 5.2 Checking for Damage in Shipping Checking Inventory of Parts 6. Hooking up the Pump 6.1 6.2 6.3 6.4 Installation of Pump Water Supply Water Filter Installation Anti-Drip Extension 7. Mist Line Layout Strategies 7.1 7.2 7.3 7.4 Light, Medium or Heavy Haze Indoor Fog Curtains Raise Humidity to Keep Dust Down Project Images and Lasers 8.
1. Equipment Supplied ! Jungle Mist Junior Anti-Drip System (Please see section 5.2 for a complete checklist.) 2.
3. Safety Information 3.3 • • • 4.4 • • • • • WARNING: Read through the entire instructions before attempting installation. Risk of electrical shock - This pump is supplied with a grounding conductor. To reduce risk of electrical shock, connect only to a properly grounded, grounding type receptacle. Plug the unit into a dedicated, fused circuit. Install pump on a flat, level, solid foundation. This pump is non-submersible.
5. Receiving and Unpacking 5.1 CHECKING FOR DAMAGE IN SHIPPING • Carefully examine contents for signs of damage in shipping. Immediately notify the carrier if damage is detected that was not visible upon receipt of shipment. 5.
6. Hooking up the Pump 6.1 INSTALLATION OF PUMP • The pump should be set inside a covered area on a level surface such as a stage or platform. Do not set it on a soft surface as the vibration will sink the unit. 6.2 WATER SUPPLY • Insure that the water source being used can supply enough water for the demand of the pump. Use a minimum ¾” hose (19 mm) with at least 40 PSI (2.8 bar) of clean water. 6.3 WATER FILTER INSTALLATION • NOTE! Use factory-supplied water filter in water supply to the pump.
6.4 ANTI-DRIP EXTENSION • With anti-drip, you can stop drips from occurring when stopping and starting the Jungle Mist Junior Anti-DripTM. Each time you stop the system, the auto-drain valve removes a slight amount of water to reduce pressure (1/4 cup) to drain into the bucket. For testing, place a bucket at rear of pump under tube coming out of the machine in the back marked DRAIN. For permanent installation run a hose from the DRAIN outlet to a convenient sewer drain.
8. Mist Line Assembly 8.1 TUBING CONNECTION • Use the supplied cutters to begin cutting the supplied high-pressure (black) tubing to the required lengths (see recommended lengths below). Be sure to measure the total length required for the mist line before cutting the tubing. Only cut what is needed. We suggest a straight line of 20 feet (6m) at first, because you can change the shape after testing the unit and the heads. • RECOMMENDED NOZZLE SEPARATION Mounting Height 8 – 10 ‘ (2.4-3m) 10-15’ (3-4.
recommended operating pressure range of 600-800 PSI (42-55 bar). If you reduce the number of nozzles, you will increase pressure. UNDER NO CIRCUMSTANCES SHOULD THE PRESSURE EXCEED 800 PSI (55 bar), as this can rupture lines and cause damage to seals and pump. This can be caused from not using enough nozzles. Extensive time would cause overheating. 8.4 Checking for Leaks • Check for leaks that may have occurred due to the tubing not being inserted beyond the o-ring seal.
9. Maintenance procedures 9.1 SYSTEM PRESSURE • Your pump includes a 2000 PSI (138 bar) high pressure glycerine-filled gauge. Check the system pressure periodically during operation The operating pressure should be between 600-800 PSI (42–55 bar). DO NOT EXCEED 800 PSI (55 bar)! Note: an air bubble will be inside the pressure gauge. This is normal. 9.2 EXTERNAL WATER FILTER INSPECTION • • Shut down water supply to pump before inspecting the filter element.
11 . Technical Data Jungle Mist Junior Anti-DripTM 110VAC P/N 100072; 230VAC P/N 100074; 12VDC P/N 100068 Case Dimensions 12" x 10" x 13" (31 cm x 25 cm x 33 cm) GPM 0.25 Weight 20 lbs (9 kg) Shipping Container 28” x 14” x 15” (71 cm x 35.6 cm x 38 cm) Shipping Weight 36 lbs (16.4 kg) Motor HP 1/4hp Electrical Power 110VAC, 60 Hz, 2 amp (AC single-phase or DC) 230VAC, 50 Hz, 1 amp 12VDC, 14 amp Maximum Pressure 800 PSI (55 bar) Maximum Inlet 40 - 125 PSI (no less than 40 PSI) Pressure 2.8 – 8.
12. Limited Warranty Conditions Jungle Mist Junior Anti-DripTM 1. Subject to the following conditions we will repair any defect or fault in the unit if it is caused by a proven factory fault and has been advised immediately after appearance and within 30 days of delivery to the end user. Insignificant deviations of the regular product quality does not guarantee replacement rights, nor do faults or defects caused by water, by generally abnormal environment conditions or Force Majeure. 2.
If you should send the unit for service, do not forget to drain water from system. Obtain your RMA # by calling CITC. Payment arrangements for repair must be made before receiving RMA # in case unit is not covered under Limited Warranty. Send unit to: CITC RMA # XXXXXXX 2100 196th Street SW Suite #138 Lynnwood, WA 98036 Tel: (888) 786-CITC or (425) 776-4950 Fax: (425) 776-5129 Website: www.citcfx.com E-mail: info@citcfx.com 2100 196th St.