LINE THERMAL PRINTER User's Manual iDP3240

34
7. SERIAL INTERFACE
7.1 Specifications
(1) Synchronizing system
Asynchronous
(2) Baud rate
2400, 4800, 9600, or 19200 bps (User selectable)
(3) Configuration of one word
Start bit: 1-bit
Data bits: 7 or 8-bits (User selectable)
Parity bit: Odd, even, or none (User selectable)
Stop bit: 1-bit or more
(4) Signal polarity
RS-232C
Mark = Logic 1 (3 V to 12 V)
Space = Logic 0 (+3 V to +12 V)
(5) Received data (RD signal)
RS-232C
Mark = 1
Space = 0
(6) Reception control (DTR signal)
RS-232C
Mark: Data transfer disabled
Space: Data transfer enabled
(7) Transmission control (TD signal)
DC1 code (11H)X-ON: Data reception enabled
DC3 code (13H)X-OFF: Data reception disabled