English FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH607 DAT E SE E Deutch T IM SY T CH 607 P mm Hg DI - Eng 1 - IN English Español Português Deutsch Français PUL /M SE ME MO RY mm A . Hg STA RT / ST OP MO DE mm S .
GENERAL REMARKS General remarks on blood pressure and blood pressure measurement • If the cuff is to be deflated quickly, depress “Start/ Stop” switch. • The attached cuff is suited for a wrist circumference of 13.5 cm to 19.5 cm. • When attaching the cuff, the body of the blood pressure monitor should be placed on the inside of your wrist. • Self-measurement is no therapy! In no case should the dosage of medication ordered by the doctor be changed.
• DO NOT measure blood pressure after the cuff has been on for a few minutes, as your arm will have built up higher blood pressure, and you will not get a valid reading. Precaution for use - Eng 3 - Français • Congestion, swelling, etc. may occur in some people. • If blood pressure is measured repeatedly, an accurate result will not be achieved. An interval of about 10 minutes should be allowed. • The memory is erased if the batteries are removed for replacement, etc.
Precaution for maintenance Cleaning method of Cuff • Do NOT store the blood pressure meter where it will be exposed to direct sunlight, high temperature (over 60°C), low temperature (below - 20°C), high relative humidity (over 95%) or in a dusty place . • Do NOT expose the blood pressure meter to undue force or vibration, or drop it. • Remove the batteries when not use for a long time period. • Do NOT disassemble the apparatus. • Do NOT bend the cuff or Air hose unnecessarily.
Reference European standard: SYSTOLIC (mmHg) This products complies with EN instructions 93/ 42/EEC (Medical Device Directive) and with the following standards: EN 1060:1995 “Noninvasive Sphygmomanometers, Part 1 General Requirements” and EN 1060: 1997 “Noninvasive Sphygmomanometers, Part 3 Supplementary Requirements for Electromechanical Blood Pressure Measuring Systems”. 180 Hypertension (severe) 160 140 130 Manufacturer: Hypertension (moderate) Name: Living Science (Shenzhen) Co., Ltd.
DEVICE DESCRIPTION 1. Name of the parts LCD display DA TE CH 60 7 mm Hg P M TIM S mmY S Hg . ST AR T/ DI ST OP mm A Hg . PU M O D E T E S E / M LSE IN Y OR EM M Setting button Mode button Recall memory button Wrist cuff Start/Stop button Batteries “AAA” 1.
English 2.
BATTERY REPLACEMENT 1. To use this unit, you must install batteries, If the battery mark “ ” is displayed, you must change both batteries. 2. Open battery cover as illustrated. Replace the two batteries, matching the (+) and (–) polarities on each battery with the polarity marks on the case. • To take the batteries out easily, pull the transparent ribbon. 3. “LR03” batteries or equivalent are suitable for this blood pressure monitor. All batteries used must be same type.
MEASUREMENT PROCEDURES - Eng 9 - Français The blood pressure is measured at the wrist. Therefore, rolling up the sleeve is no longer necessary. The pressure cuff has integrated into the wristlet. Wind the wristlet around your left wrist. The wrist should be free. The display is at the inner of the wrist. Deutch 1. Attaching of wrist cuff Español Português Italiano 4) Press the “Mode” switch then “Minute” starts flashing. Press “SET” button to set the correct Minute.
• Apply the wrist cuff to the wrist and make sure it is not too loose or too tight. If the wrist cuff is applied inappropriately, it may display an error or abnormal values. Pull the wristlet tight and close the “Burr closure”. Wrist circumference: 13.5-19.5 cm. Measurement Procedures for People With a Weak Pulse • Apply the middle part of the wrist cuff to the artery in the wrist to measure blood pressure. 2. To start the Measurement CAUTION Do not grasp the unit too tightly.
4. Automatic power-off function If the unit is left on after measurement, an automatic power-off function turns the power off after approximately 1 minute. To continue measurement, press the “START/STOP” switch turning the unit on. After, wind the wristlet around your left wrist. - Eng 11 - Français To discontinue a measurement for any reason, press the “START/STOP” switch. This causes the “wrist cuff” to deflate rapidly.
5. Memory recall 6. Memory clear function You can recall stored data by pressing the “Memory” switch, except when performing a measurement. • Up to 99 sets of measurement results are automatically stored in memory, and memory cell No. 1 is always used to store the oldest set of results. • Press “Memory” switch, the memory cell number with the stored measurement results (Systolic / Diastolic and Pulse with Date/Time) are displayed for 1 minute.
DISPLAY MARK Appears when the accurate blood pressure could not be obtained accurately. Press “Start/Stop” switch again and re-measure. Or check cuff if wrapped at the wrist or according to instructions. Check palm if exerting effort. Check if talking or moving during measurement. Check if posture is incorrect. Replace batteries Appears when the battery voltage is excessively low or the positions of batteries are incorrect. Replace all batteries with new ones.
SPECIFICATIONS Model Number Measuring Principle Measurement Localization Cuff Arm Circumference Range Measurement Range Accuracy Pressure Pulse Pressure Pulse Pressure Pulse LCD Indication Marks LCD Viewing Size Digit Size Switch Inflation Deflation Exhaust Rated Voltage Power Source Power Consumption Battery Life Automatic Power Off Function Clock Function Memory Function Dimensions Weight Operating Environment Storage Environment Accessories Temperature Humidity Temperature Humidity CH607 Oscillome