Axis Specifications Parameters
II - 54
#2078 G1inps G1 in-position width
Set the in-position width for G1.
Between SV024 and this parameter, the parameter with a larger value will be applied.
When "0" is set, this parameter will be invalid: only SV024 will be available.
---Setting range---
0.000 to 99.999 (mm)
#2079(PR) chcomp Chopping compensation coefficient
Set the coefficient to be applied to the compensation amount for the insufficient amount
caused by servo delay during chopping.
---Setting range---
0 to 10 (standard value: 8)
#2080 chwid Bottom dead center position width
Set the tolerance between the commanded stroke and actual stroke.
Compensation will be applied during chopping so that the result of [command width -
maximum stroke of top or bottom dead point/ 2] will be within this tolerance.
---Setting range---
0 to 10.000 (mm)
#2081 chclsp Maximum chopping speed
Set the clamp speed in chopping operation.
When "0" is set, the clamp speed will be determined by "#2002 clamp".
---Setting range---
0 to 60000 (mm/min)
#2082 a_rstax Restart position return order
Set the No. for each axis in order from the 1st automatically returning axis to the restart
position.
When "0" is set, the axis will not return.
Note that when "0" is set for all axes, all of the axes will return simultaneously.
---Setting range---
0 to 8
#2086 exdcax1 External deceleration speed 1
Set the upper limit of the feedrate when the external deceleration signal is ON and only one
axis is moved. In automatic operation, the upper limit of the combined speed is applied.
Set #2086 when using the external deceleration for each axis, and #2161 - #2165 when
using the external deceleration 2nd step or later.
This parameter is enabled when "#1239 set11/bit6" is set to "1".
---Setting range---
1 to 1000000 (mm/min)
#2116(PR) v_axis Hypothetical axis
Select whether the axis is used as a hypothetical axis or an actual axis.
When not using the hypothetical linear axis control, set "0" for all axes.
0: Actual axis
1: Hypothetical axis
#2117(PR) v_axno Hypothetical axis No.
In hypothetical linear axis control, set the relation of the actual axis to the hypothetical axis
in the hypothetical plane.
For actual linear axes, set the axis No., used in the part system, of the hypothetical axis
parallel to the actual axis.
For actual rotation axes, set the axis No., used in the part system, of the hypothetical axis
vertical to the actual linear axis.
Setting for the PLC axes will be ignored. In multi-part system, axes in another part system
cannot be set.
0: Actual/ hypothetical axis out of the hypothetical plane
1 or later (axis Nos. used in the part system): Hypothetical axis No. to set
#2118(PR) S_DSI Speed monitor Door selection
Select which door group of the speed monitoring the spindle belongs to.
The belonging door group corresponds to the following bits of the parameter.
bit0 : Door 1
bit2 : Door 2
:
bitF : Door 16
It is possible to belong to two or more door groups.
(Example) 0013: Belongs to door 1, 2, and 5 groups.
Belongs to door 1 group when "0000" is set.
The speed monitoring will not be executed when "#2313 SV113 SSF8/BitF" is OFF
regardless of this parameter.
The selected door group must be set when setting the synchronous control.
The spindle/C axis control enables the door selection in "#3071 SscDrSelSp" for the
corresponding spindle.