Specifications

Table Of Contents
II Parameters
PLC Axis Indexing Parameters
II - 167
#12877 PSW04-1 PSW4 area setting 1
Set "PSW4 area setting" 1 and 2 to specify the area where the position switch 4 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12878 PSW04-2 PSW4 area setting 2
Set "PSW4 area setting" 1 and 2 to specify the area where the position switch 4 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12879 PSW05-1 PSW5 area setting 1
Set "PSW5 area setting" 1 and 2 to specify the area where the position switch 5 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12880 PSW05-2 PSW5 area setting 2
Set "PSW5 area setting" 1 and 2 to specify the area where the position switch 5 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12881 PSW06-1 PSW6 area setting 1
Set "PSW6 area setting" 1 and 2 to specify the area where the position switch 6 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12882 PSW06-2 PSW6 area setting 2
Set "PSW6 area setting" 1 and 2 to specify the area where the position switch 6 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12883 PSW07-1 PSW7 area setting 1
Set "PSW7 area setting" 1 and 2 to specify the area where the position switch 7 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12884 PSW07-2 PSW7 area setting 2
Set "PSW7 area setting" 1 and 2 to specify the area where the position switch 7 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12885 PSW08-1 PSW8 area setting 1
Set "PSW8 area setting" 1 and 2 to specify the area where the position switch 8 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)