2. BASIC SPECIFICATIONS
2.1 Model Classifications
The models are classified by the following designation method:
CBM-270 - R F 120 - N
∗ Special Switching Power Source and Power Cord
Switching power source : 27AD (Input: 100 to 240V AC)
Power cord : 100V AC --- 2-core cord
120V AC --- 2-core cord
230V AC --- 2-core cord
Cord length : Power cord(For AC Input) --- Approx. 1.8 m
Secondary side (For DC Output) --- Approx. 1.8 m
Model Name
CBM-270: Standard Model
Label Paper Print Function
N: None
L : Label interval detection
M: Black mark detection
AC Power Cord
120: 120 V AC
230: 230 V AC
International Characters
F: International
Interface
R: Serial (RS-232C)
P: Parallel