User`s manual

CBM-270 User’s Manual
20
CITIZEN
6. PARALLEL INTERFACE
6.1 Specifications
Data input system : 8-bit parallel (DATA1 to DATA8)
Control signals : ACK, BUSY, STROBE, FAULT, PE, RESET
Applicable connectors : Printer side : 57LE-40360 (Anphenol) or its equivalent
Cable side : 57-30360 (Anphenol) or its equivalent
6.2 Connector's Pin Configuration
No. Signal Name No. Signal Name
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
STROBE
DATA 1
DATA 2
DATA 3
DATA 4
DATA 5
DATA 6
DATA 7
DATA 8
ACK
BUSY
PE
+5VDC
GND
FRAME GND
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
TWISTED PAIR GND
RESET
FAULT
GND
6.3 Input and Output Signals
6.3.1 Input and Output Signals
(1) Input signals to the printer
DATA : 8-bit parallel signal (Positive logic)
STROBE : Strobe signal to read the 8-bit data (Negative logic)
RESET : Signal to reset the entire printer (Negative logic); 1 ms or more