User`s manual

CBM-270 User’s Manual
42
CITIZEN
ESC @
[Function] Initializing the printer
[Code] <1B> H <40> H
[Outline] Clears data stored in the print buffer and brings various settings to the initial state (Default
state).
[Caution] Data inside the internal input buffer are not cleared.
Dip switches setting are red once again.
[Sample Program] [Print Results]
LPRINT CHR$ (&H1B) ; " ! " ; CHR$ (&H30) ;
LPRINT CHR$ (&H1B) ; "V" ; CHR$ (1) ;
LPRINT "AAA" ; CHR$ (&HA) ;
LPRINT CHR$ (&H1B) ; "@" ;
LPRINT "AAA" ; CHR$ (&HA) ;
END
ESC D [ n ] k NUL
[Function] Setting horizontal tab position
[Code] <1B> H <44> H [<n>] k <00> H
[Range] 1 n 255
0 k 32
[Outline] Specifying a horizontal tab position.
"n" indicates the no. of columns from the beginning to the horizontal tab position. At this
time, n= set position 1 is to be specified. For example, to set the position at 9th column,
n=8 is to be specified.
k denotes the number of horizontal tab positions you want to set.
The tab position is set at position where it is "character width x n" from the line beginning.
The character width, at this time, includes the rightward space amount. In double wide
characters, it is made double of the ordinary case.
Tab positions can be specified are maximum 32. Specifying exceeding this is ignored.
<n> k, which denotes a setting position, is input in the increasing order and ends at <00>
H.
ESC D NUL clears all the set tab positions. Following clearing, horizontal tab
command is ignored.
[Caution] When the data, <n> k, is equal to or smaller than its preceding data, <n> k-1, it is assumed
that tab setting is finished. If this is the case, the next data onward will be processed as
normal data.
When the data, <n> k, exceeds a 1-line print area, set the horizontal tab position, assuming
"Set digit position = Maximum print digits + 1." The horizontal tab position does not
change even if the character width is altered after setting the horizontal tab position.
[Default] Initial value is specified for each eight characters(9th.17th.25th.33rd columns) of Font A.
[See Also] HT
[Sample Program] [Print Results]
See Sample Program and Print Results for HT on Page 32.
Each setting has been
initialized by the reset
command.