Specifications
- 103 -
fn = 11: Function 11 Setting Communication Conditions of Serial
Interface
GS (E pL pH fn a d1...cdk fn = 11
[Code] <1d>H<28>H<45>H pL pH fn a d1..dk
[Range] 3≤(pL + pH x256)≤65535 (0≤pL≤255, 0≤pH≤255)
fn = 11
1≤a≤4 (Not changed in other than specified range)
48≤d≤57 (Not changed in other than specified range)
1≤k≤6
[Outline] Sets the communication conditions of serial interface specified by “a”.
• a = 1: Setting baud rate
Baud Rate d1 d2 d3 d4 d5 d6
2400 50 (“2”) 52 (“4”) 48 (“0”) 48 (“0”) — —
4800 52 (“4”) 56 (“8”) 48 (“0”) 48 (“0”) — —
9600 57 (“9”) 54 (“6”) 48 (“0”) 48 (“0”) — —
19200(Default) 49 (“1”) 57 (“9”) 50 (“2”) 48 (“0”) 48 (“0”) —
38400 51 (“3”) 56 (“8”) 52 (“4”) 48 (“0”) 48 (“0”) —
• a = 2: Setting to specified parity
d1 Parity Setting
48 (Default) No parity
49 Odd parity
50 Even parity
• a = 3: Setting to specified flow control
d1 Flow Control
48 (Default) DSR/DTR
49 XON/XOFF
• a = 4: Setting to specified data length
d1 Setting Data Length
55 7-bit length
56 (Default) 8-bit length
• Operates only in printer function setting mode.
• Which of dip SW or memory SW is used at initialization depends on “Selecting
communication condition setting” of dip SW1-1.