Specifications

- 94 -
fn = 5: Function 5 Setting Customized Value
GS (E pL pH fn [a1 n1L n1H]...[ak nkL nkH] fn = 5
[Code] <1d>H<28>H<45>H pL pH fn [a1 n1L n1H]...[ak nkL nkH]
[Range] 4(pL + pH x256) 65535
fn = 5
1a3 a = 5, 6, 116, 201, 202
1(nL + nH x256) 65535
[Default] Described in the processing table for “a”.
[Outline] • Sets the customized value set in “a” to (nL + nH x256).
a Function
5 Selects printing density.
6 Selects printing speed.
116 Selects printing color.
201 Sets ACK output position (only parallel I/F).
202 Selects input buffer full Busy output/cancel timing (idle capacity).
• a = 5: Sets printing density to the level specified by (nL + nH x256).
(nL + nH x256)
Printing Density
65530 0.7 times
65531 0.75 times
65532 0.8 times
65533 0.85 times
65534 0.9 times
65535 0.95 times
0 (Default) 1
1 1.05 times
2 1.1 times
3 1.25 times
4 1.2 times
5 1.25 times
6 1.3 times
7 1.35 times
8 1.40 times