Chapter 3: High Availability
NetScaler 9000 Series Installation and Configuration Guide - Volume 1 3-11
NSICG60_JAN05
Note: The maximum node ID for NetScaler 9000 systems in a high
availability setup is 64.
3. To save the configuration enter
save config in the CLI.
4. Verify the configuration using the following CLI command:
show node
This displays the Node ID, IP Address and Configuration mode for both
NS1 and NS2. The following should be the display:
> show node
2 configured nodes:
1) Node ID: 0
IP: 10.102.3.210
Node State: UP
Master State: Primary
Sync State: Enabled
Enabled Interfaces : 1/2 1/1
Disabled Interfaces : None
HA MON ON Interfaces : 1/2 1/1
SSL Card Status: UP
2) Node ID: 1
IP: 10.102.3.201
Node State: UNKNOWN/DOWN
Master State: Unknown
Sync State: Unknown
Enabled Interfaces: Unknown
Disabled Interfaces : Unknown
HA MON ON Interfaces : Unknown
SSL Card Status: Unknown
Done