Chapter 2 Installation, Configuration and Management
NetScaler 9000 Series Installation and Configuration Guide - Volume 1 2-21
NSICG60_DEC04
Figure 2-21 Front panel of NetScaler 9400
4. Connect a terminal (which can be a computer supporting VT100 terminal
emulation) to the console port on the front of the unit.
Note: The terminal that you supply must have a baud rate and character
format configured to 9600 baud, 8 data bits, 1 stop bit and no parity.
5. Power-on the NetScaler 9400 system.
Figure 2-22 Back panel of NetScaler 9400
a. Plug-in the power cord that comes with the unit on the back of the
NetScaler 9400 system. See the above figure.
b. Depress the
On/Off switch present at the back of the unit.
The green LED appears lit.
WARNING! After the initial power-on, to power-off the NetScaler 9400
system follow the steps as described in the “Powering-Off the
NetScaler 9000 system” on page 44.
NetScaler 9400 system operation starts.