Instruction manual

Chapter 2 Installation, Configuration and Management
2-24 NetScaler 9000 Series Installation and Configuration Guide - Volume 1
NSICG60_DEC04
Note: The terminal that you supply must have a baud rate and character
format configured to 9600 baud, 8 data bits, 1 stop bit, and no parity.
5. Power-on the NetScaler 9000 system. Refer to Figure 2-25 on page 24 for
the location of the
ON/OFF button.
Figure 2-25 Back panel of NetScaler 9800-T or NetScaler 9800-SX system
a. Plug in the two power cords that come with the unit into the back of
the NetScaler 9000 system (see Figure 2-25 for the location of the
power).
MAKE SURE
that you plug in BOTH power cords.
For 2U NetScaler systems with only one power supply cable plugged
in, the system will emit a high pitched alert. This alert can be shut off
in one of three ways, depending upon the hardware version.
1. If present, press the small red button at the back of the box near the
power plugs. This will have to be done each time the system is
powered on.
2. If the red button on the rear of the case is not present, check on the
front of the unit around the LCD screen. You will need to remove the
faceplate to see the button for silencing the alarm.
3. If neither of these buttons are present on the unit, power cables
must be used. The alarm cannot be manually overridden on these
units.
b. Turn the switch to the right of the three fans on the back of the unit to
the on position.