User Manual

Chapter 11
BOSCH HDI EDC 15C2 INJECTION SYSTEM AND PARTICLE FILTER
92
Supplier MARWAL:
HEIGHT OF THE FLOAT AXIS IN
RELATION TO THE BASE LEVEL
RESISTANCE
14 mm
350 ± 11 ohms
41 mm
300 ± 10 ohms
72 mm
250 ± 10 ohms
104 mm
200 ± 9 ohms
138 mm
150 ± 9 ohms
171 mm
100 ± 8 ohms
204 mm
50 ± 2 ohms
Note: The fuel sender cannot detect a variation in fuel level of less than 7
litres precisely.