User Manual

Chapter 12
BOSCH HDI EDC 15C2 INJECTION SYSTEM AND PARTICLE FILTER
103
E - OPERATION
The BSI determines the passenger compartment heating requirement when the
engine is started depending on the exterior air temperature and the coolant
temperature.
The built-in systems interface operates the additional heater in the following
conditions:
engine operating for more than 60 seconds,
engine speed above 700 rpm,
battery voltage greater than 12 volts (positive electrical balance),
coolant temperature above 40°C.
The built-in systems interface controls the heater stages progressively:
first stage,
second stage,
second stage and first stage.
The additional heating is switched off when the temperature conditions so allow
(curve).
cardiagn.com