Installation Guide
2
Cidron Slimline (VG3 QR) Reader -
Technical specications
Operating frequency 13,56MHz.
Reading technologies
MIFARE® CSN 4 byte, MIFARE® CSN 7 byte, MIFARE® Classic, MIFARE® Plus
and MIFARE DESFire® EV1. Also supports other ISO 14443 A/B* compatible cards.
*Not all ISO14443 B cards have been implemented in the reader, please contact
Civintec Global for more details on current status.
Mobile ID
ISO18092NFC, BLE (Bluetooth low energy)
Barcode/QR scanner
Area image 640 x 480 pixels, Filed of View 68°(H) x 51(V)
Decode range: 20mm-150mm(QR 20MIL)
Roll/Pitch/Yaw: 360°, ±55°, ±55°
Multiple formats supported (1D & 2D Codes): QR Code, Micro QR code,
PDF417, Code 128, Code 39 and most mainstream 1D and 2D barcodes.
Secure Access Module
(SAM)
MIFARE SAM AV2, external SIM card connection slot.
Communication protocols Wiegand, RS485 (OSDP 1, OSDP 2, including Secure channel), BLE.
Reading output format 24-1024 (excluding parity bits)
Keypad output format Wiegand 4bit, Wiegand 8bit (Dorado), Wiegand 26bit, OSDP ASCII format.
Keypad
12 digit keypad in 4 rows of 3 keys in each row with congurable
backlight in blue color. Control features On/O/Auto indicators.
Light itensity can be adjusted.
Indicators LED, Green, Red and Yellow (Bi-color). Backlight in blue color. Buzzer.
Power supply 9 – 30VDC
Input/Output
4 input for LED and buzzer and 2 congurable General Purpose Input/Output
(GPI/O). The GPI/O’s are push/pull type which provides 5VDC as output when “high”
on each respective GPI/O connection pin.
Tamper alarm
Built-in mechanical tamperswitch which allows for
indication both break o protection and opening of the reader.
Operating temperature
RFID reader: -40° ~ +70°C (With thermostat controlled embedded heater)
When installing readers in environments with extreme heat(above + 50°C)
it is recommended to utilize the climate protection SC9901-V which provides
additional shading to the reader.
QR code module: -20°~ +55°C
Heater Thermostat controlled embedded heater.
Operating humidity 0 – 95% RHNC (Relative Humidity No Condensation)
Ingress Protection
Classication
IP65 require together with weather protection cover SC9901-T or SC9901-V.
Housing dimension L=180mm, H=95mm, W=63mm
Conguration Methods Conguration card, Congcard software or factory congured readers.
Compliances FCC, CE