Anti-Cavitation Hytrol Valve
100-01KO
Full Open Operation
When pressure in the
cover chamber is
relieved to a zone of lower pressure,
the line pressure at the valve inlet
opens the valve, allowing full flow.
Modulating Action
The valve holds any intermediate posi-
tion when operating pressures are
equal above and below the
diaphragm. A Cla-Val “Modulating
Pilot Control will allow the
valve to automatically com-
pensate for line pressure
changes.
Tight Closing Operation
When pressure from the valve inlet
is applied to the cover chamber, the
valve closes drip-tight.
MODEL
On-Off Control
Modulating
Control
On-Off Control
Principle of Operation
Virtually Cavitation Free Operation
Severe Service Design - High Pressure Differentials
Reduced Noise and Vibration
316 Stainless Steel Disc Guide and Seat Standard
Drip-Tight, Positive Sealing
Service Without Removal From Line
Retrofit to Standard Hytrol Valves
The Cla-Val Model 100-01KO Anti-Cavitation Hytrol Valve is designed for appli-
cations where there is a high potential for damage from cavitation. Specify this
valve series for a wide variety of control valve applications having pressure dif-
ferentials up to 300 psid or for relief valves having atmospheric discharge up to
150 psid.
The 100-01KO Hytrol main valve provides optimum internal pressure control
through a unique anti-cavitation trim design. Constructed of 316 Stainless Steel,
the seat and disc guide trim components feature dual interlocked sleeves con-
taining radial slots that deflect internal flow to impinge upon itself in the center of
the flow path, harmlessly dissipating the potential cavitation damage. This
unique design also lessens the possibility of fouling if large particles in the water
are present due to the large flow path of the radial slots.
The 100-01KO Hytrol is the basic valve used in Cla-Val Automatic Control Valves
for high differential applications requiring remote control, pressure regulation,
solenoid operation, rate of flow control, or liquid level control.
The Anti-Cavitation Trim components can be retrofitted to existing valves if the
application indicates an appropriate need. Please consult factory for details.