Instruction Manual

CLA-VAL
Copyright Cla-Val 2013 Printed in USA Specifications subject to change without notice.
P.O. Box 1325 Newport Beach, CA 92659-0325 Phone: 949-722-4800 Fax: 949-548-5441 E-mail: claval@cla-val.com Website cla-val.com
©
Pilot System Specifications
When Ordering,
Please Specify
1. Catalog No. 60-31 or
No. 660-31
2. Valve Size
3. Pattern - Globe or Angle
4. Pressure Class (Flanged)
5. Trim Material
6. Electrical Selection
7. Desired Options
8. When Vertically Installed
(Flow Direction)
Note: For optimum operation of built-in check feature, installation with valve stem vertically position is recommended.
E-60-31/660-31 (R-1/2013)
Auto
Off
Hand
L1
SW
1
A
3CR
3
L2
1CR
H
1CR
1CR
3CR
1
N.C.
2CR
PVS
2CR
3CR
M
COM.
SW
2
N.O.
3CR
2
2CR
Auto-Off-Hand = Selector Switch
1CR = Relay, DPST Normally
Open
2CR = Relay, DPST Normally
Open
3CR = Relay, TPST Normally
Open
SW
1
= Switch, Remote Start,
Automatic
SW
2
= Switch, SPDT, Valve Limit
Switch Connect to N.C.
Terminal
PVS = Pilot Valve Solenoid
M = Pump Motor Starter
Note: SW
2
and PVS supplied by
Cla-Val Co. All other electrical items
supplied by customer. SW
2
is
included in the X105L switch
assembly which is mounted on the
pump control valve cover.
Shown In Pump Off Position
60-31
Valve
Selection
100-04 Pattern: Globe (G), Angle (A), End Connections: Threaded (T), Flanged (F) Indicate Available Sizes
Inches 2 2
1
2 3 4 6 8 10 12 14
mm 50 65 80 100 150 200 250 300 350
Basic Valve
100-04
Pattern
G, A G, A G, A G, A G, A G, A G, A G, A G, A
End Detail T, F T, F T, F T, F T, F T, F F F F
Suggested
Flow
(gpm)
Maximum
210 300 460 800 1800 3100 4900 7000 8400
Maximum
Intermittent
260 370 580 990 2250 3900 6150 8720 10540
Suggested
Flow
(Liters/Sec)
Maximum
13 19 29 50 113 195 309 442 530
Maximum
Intermittent
16 23 37 62 142 246 387 549 664
100-04 Series is the full internal port Hycheck.
660-31
Valve
Selection
100-23 Pattern: Globe (G), Angle (A), End Connections: Flanged (F) Indicate Available Sizes
Inches 3 4 6 8 10 12 14 16 18 20 24
mm 80 100 150 200 250 300 350 400 450 500 600
Basic Valve
100-23
Pattern
GG, AG, AG, AGGGGGGG
End Detail FFFFFFFFFFF
Suggested
Flow
(gpm)
Maximum
260 580 1025 2300 4100 6400 9230 9230 16500 16500 16500
Suggested
Flow
(Liters/Sec)
Maximum
16 37 65 145 258 403 581 581 1040 1040 1040
100-23 Series is the reduced internal port size version of the 100-04 Series.
Temperature Range
Water: to 180°F Max
Materials
Standard Pilot System Materials
Pilot Control: Bronze ASTM B62
Trim: Stainless Steel Type 303
Rubber: Buna-N
®
Synthetic Rubber
Optional Pilot System Materials
Pilot Systems are available with optional
Stainless Steel or Monel materials
Solenoid Control
Body:
Brass ASTM B283
Enclosure:
General Purpose, Watertight 1,2,3,3S,4,4X
Optional: Class I, Division 2, Hazardous Locations
and Watertight Type 3, 3S, 4, 4X
Voltages:
100-240 V 50-60 Hz AC or DC
24-99 V 50-60 Hz AC or DC
2-24 V DC
Manual Operator Standard
Max. operating pressure differential: 300 psi
Coil:
Insulation molded Class F
Watts AC 2
Wiring Diagram