User's Manual

IDSmart UHF Security Gate User Manual
© Copyright 2014 ClarIDy Solutions, Inc. All rights reserved. 17/40
3. The System Connectivity
The system is configured to boot up automatically into embedded Linux. The blue LED light
bar will be turned on when the equipment is ready. The following section provides user with
more information regarding the configuration of the peripherals or components.
3.1. Ethernet Port
Two Ethernet port sockets are located at the lower part of the main panel. One of the port
is labeled as "Reader Setup Port" and the other is labeled as "LAN Comm. Port"
Reader Setup Port (Item #2) LAN Comm. Port (Item #1)
MAC Address 00:05:7B:82:02:5C 48:D8:FE:F0:00:01
IP Address 192.168.25.203 192.168.10.210
Usage Reserved for reader setup, debug
and testing only, not for application.
Connect to Local Area Network
for communication with other
system and remote access to the
system.
Both port are set to static IP address. The reader setup port doesn't need to be connected
to the network, it is only use for setup and tuning. The LAN communication port is the main
interface between the equipment and the network server or remote access client.
To make the equipment accessible for local area network, either adjust the network to
192.168.10.x or change the default IP address of the LAN Comm. Port. Refer to section 4.2.
Accessing and Changing the UHF Security Gate Network Configuration for information on how
to change IP address of the LAN Communication. Port.
Note: Users should not change the IP Address of the reader through the Reader
Setup Port. Changing the IP Address will disconnect the reader from the embedded
board. If user has accidentally change the IP address using the reader test tool. Use the
tool to search the reader and change it back to the default IP address.