User's Manual

IDSmart UHF Security Gate User Manual
© Copyright 2014 ClarIDy Solutions, Inc. All rights reserved. 19/40
3.6. UHF RFID Reader
The 16-port UHF RFID reader is conformed to EPC UHF Class 1 Gen 2 and capable of
supporting ISO18000-6C protocol. It is connected to the Ethernet interface of the embedded
board. The reader and the embedded board each has a fixed IP address assigned ensuring
direct communication between these two units..
Setting Value
Embedded Board Ethernet Port IP 192.168.25.210
Embedded Board Network Mask 255.255.255.0
UHF RFID Reader IP 192.168.25.203
UHF RFID Reader Network Mask 255.255.255.0
Note: User should not change the default IP address of the UHF RFID Reader.
Besides the internal Ethernet interface that connected to the Embedded Board. The
equipment also includes an external Ethernet Port (i.e. The Reader Setup Port) for
accessing the reader externally. This is particularly useful when user wish to calibrate
and tune the equipment for tag detection.
4. Modifying the Default Network Configuration
The security gate's network configuration (i.e. the configuration of LAN communication port)
can be changed by accessing the equipment through remote access terminal. SSH protocol is
selected for better security. This LAN communication port is the only port that user may change
according to the deployed networking environment.
4.1. Initial Network Configuration of UHF Security Gate
The factory default network configuration of the UHF Security Gate is as follows.
IP Address 192.168.10.210