Specifications

148
UNGO – Programming Guide
SR6000 (2-Way Remote Start with Security Combo)
MENU 1
Feature Default LED ON LED OFF Setting
Number (Press Channel 1) (Press Channel 2)
1-1 Active Mode Passive Mode
1-2 Chirps ON Chirps OFF
1-3 Ignition Lock ON Ignition Lock OFF
1-4 Ignition Unlock ON Ignition Unlock OFF
1-5 Active Locking Passive Locking
1-6 Panic with Ignition ON Panic with Ignition OFF
1-7 Door Lock Pulse Duration 0.8 Seconds Door Lock Pulse Duration 3.5 Seconds
1-8 Forced Passive Arming ON Forced Passive Arming OFF
1-9 Automatic Engine Disable ON Automatic Engine Disable OFF
1-10 Armed When Driving Anti-Carjacking System
1-11 Anti-Code Grabbing ON Anti-Code Grabbing OFF
MENU 2
Feature Default LED ON LED OFF Setting
Number (Press Channel 1) (Press Channel 2)
2-1 Siren Output Constant Siren Output Pulsed
2-2 30-Second Siren Duration 60-Second Siren Duration
2-3 False Alarm Prevention Circuitry ON False Alarm Prevention Circuitry OFF
2-4 Progressive Door Trigger Instant Door Trigger
2-5 Override Switch Input: 1 Pulse (1)* Override Switch Input: 2 (2)*, 3 (3)*, 4 (4)*, 5 (5)*
2-6 Open Zone Bypass Notice ON Open Zone Bypass Notice OFF
2-7 Ignition Controlled Dome Light ON Ignition Controlled Dome Light OFF
2-8 Single Unlock Pulse Double Unlock Pulse
2-9 FAD with Channel 2 ON FAD with Channel 2 OFF
2-10 Channel 4: Validity (1)* Channel 4: Latched/Latched (2)*, Reset with
Ignition (3)*, 30-Second Timed (4)*, 60-Second
Timed (5)*, 90-Second Timed (6)*
2-11 Channel 5: Validity (1)* Channel 5: Latched/Latched (2)*, Reset with
Ignition (3)*, 30-Second Timed (4)*, 60-Second
Timed (5)*, 90-Second Timed (6)*