User Guide
32
To exit the learn routine:
One long chirp indicates that Learn Routine has been exited. Learn Routine will be exited if any of the
following occurs:
➤➤
Ignition is turned off.
➤➤
Door is closed.
➤➤
Override switch is pressed too many times.
➤➤
More than 15 seconds elapse between steps.
remote configurations
The remotes can be programmed with the standard or single button arm/disarm configurations by
using the Auto Learn functions in the Remote Coding section.
standard configuration
A remote that uses the standard configuration operates similarly to many factory keyless entry remotes.
A standard configuration remote allows arming, disarming, and panic mode activation with separate
buttons. When programmed for standard configuration, the remote buttons are assigned to the fol-
lowing functions:
operates Arm only
operates Disarm only
operates Channel 2 and Silent Arm/Disarm
operates Panic
and operate Channel 3
The standard configuration also allows the user to utilize Remote Sensor Bypass, a feature that cannot
be accessed from a single button arm/disarm configuration remote.
single button arm/disarm configuration
When programmed for single button arm/disarm configuration, the remote buttons are assigned to the
following functions:
operates Arm/Disarm/Panic
operates Channel 2 and Silent Arm/Disarm
and operate Channel 3