User Guide

34
security diagnostics
The system stores the last two full triggers in memory. These are not erasable. Each time the unit sees
a full trigger, the older of the two triggers in memory will be replaced by the new trigger. To access long
term event history:
1. With the ignition off, press and hold the Override switch.
2. Turn on the ignition.
3. Release the Override switch.
4. Press and release the Override switch within five seconds. The LED will flash in
groups indicating the last two zones that triggered the unit. The LED will flash for one
minute or until the ignition is turned off.
NNOOTTEE::
The Warning Zone triggers are not stored to memory and will not be reported.
remote sensor bypass
Remote Sensor Bypass allows the operator to select which inputs and sensors are active during a par-
ticular arming cycle. For a full description of Remote Sensor Bypass operation for testing purposes refer
to the Owner's Guide.
anti-carjacking system
This is an optional feature designed to disable a vehicle during a carjacking event. It must be pro-
grammed in the features menu and the Starter Kill must be installed for it to work properly. For opera-
tional instructions when testing the Anti-Carjacking System refer to the Owner's Guide.