Installation & Assembly
4
Electrical Requirements
ALL CONNECTIONS MUST BE GFCI (Ground Fault Circuit Interrupted) PROTECTED
1. Whirlpool and Total Massage units require dedicated 20 Amp, 120V service.
2. You must provide a receptacle with a 20-amp configuration.
3. See local codes for proper wire size. If not specified, use #12 Copper only wire.
4. Optional Factory Installed Heater requires its own dedicated 20 amp service.
The unit must be connected to a circuit interrupter (GFCI) provided by the installer. The (GFCI) breaker
should be tested on a routine basis. To test the (GFCI) breaker, push the test button. The GFCI should
interrupt power. To restore power, push the RESET button. If the GFCI fails to operate in this manner
there is ground current flowing, indicating the possibility of an electrical shock. Do not use the unit.
Disconnect the unit and have the problem corrected by a qualified service representative before using.
DANGER: RISK OF ELECTRICAL SHOCK. All pumps and blowers must be connected to a ground fault circuit
interrupter (GFCI) protected outlets. Standard Line Total Massage units can be operated on a single
service. All heaters must be connected to a ground fault circuit interrupter (GFCI) protected outlets,
separate from the pump and/or blower.
Use Illustration C as a guide for rough–in measurements given on page following