Maintenance
Rear Squeegee Blade Replacement
If the rear squeegee blade is worn and does not dry the oor well,
follow this procedure:
1. Remove the squeegee assembly from the machine.
2. Remove the squeegee blade and inspect it.
3. Rotate the squeegee blade to obtain a new cleaning edge.
Replace if necessary.
4. Reinstall the squeegee blade.
5. Reinstall the squeegee assembly on the machine.
6. Readjust the settings on the squeegee as required (see
“How to Adjust Squeegee”).
Squeegee Maintenance
The squeegee blade may be rotated for longer life.
Keep sharp corner on oor for best cleaning
results. See gure 40. To rotate follow this
procedure:
1. Remove Clamp.
2. Remove blade and rotate to new edge.
3. Replace squeegee.
4. Replace clamp.
Every 250 hrs (BOOST Only)
1. Isolators are expected to last 250-1,000 hours depending on
the application.
2. Replace lower isolators annually or after every 250 hours,
whichever comes rst.
Cleaning the Vacuum Hoses
Make sure the squeegee is over a suitable drain.
1. Use a garden hose to ush through the recovery hoses.
2. Side Squeegee - Position garden hose to the squeegee
side of the hose and ush thoroughly.
3. Recovery Hose - Position water hose
inside recovery tank. Recovery hose is located behind
threaded lip (see gure 41, A). NOTE: Do not place hose
in vacuum intake tube (see gure 41, B), damage will
occur.
Figure 40
Figure 41