Brush Control Pedal. See Figure 5.
The brush control pedal is at the back of the machine
in the lower right corner. Use your foot to operate the
pedal. To lower the brush, push the pedal down and to
the left, releasing it from the locked position. To raise
the brush, push the pedal down and to the right
engaging the lock.
Brush Tilt Control.
The brush tilt control is on the left side by the
motor. To access the motor, turn off the key and
remove the squeegee cable, and undo the tank
clamps. To adjust how the machine pulls, loosen the
screw. Tilt the motor forward to decrease the brush-
assist traverse. Tilt the motor back to increase the
brush-assist traverse. After adjustment retighten the
screw.
The Float Shut-Off. See Figure 6.
The float shut-off is in the back of the recovery tank.
When the liquid raises the float, the float switch will
automatically turn the vacuum motor off. To continue
working you must drain the recovery tank.
The Squeegee Handle. See Figure 7.
The squeegee handle is at the back of the
machine in the middle. To lower the squeegee, pull
the handle to the right and lower. To raise the squee-
gee, lift the handle up and push to the left.