HOW TO PREPARE THE MACHINE FOR OPERATION
How To Install The Batteries
The Vision 21i and Vision V machines use four 6-volt
or two 12-volt batteries. The batteries are located in
the battery compartment under the recovery tank.
To Install the batteries, follow this procedure:
1. Set the parking brake.
2. Make sure both tanks are empty.
3. Disconnect the hoses from the recovery tank
(upper tank) & unplug the vac motor.
Remove the recovery tank.
4. Remove the two screws that attach the
solution tank (lower tank) to the back of the
frame, leaving the two angle brackets
attached to the tank.
5. Disconnect the two hoses under the right
side and remove the solution tank.
6. Place the batteries in the tray as shown in
figure #7a, #7b, or #7c.
WARNING: Lifting batteries without
help could result in an
injury. Get help to lift the
batteries. The batteries are
heavy.
WARNING: Working with batteries can
be dangerous. Always
wear eye protection and
protective clothing when
working near battiers.
NO SMOKING!
7. Connect the battery cables between
batteries and install long battery cable
assembly as indicated. See figure #7.
8. Join the connector from the battery pack to
the connector on the control panel. See
figure #8.
9. Install the tank, reconnecting hoses and
replace the two screws attaching the
solution tank to the rear of the frame.
NOTE: Charge the batteries before using the
machine.
Figure #7a
Figure #7b
Figure #7c
Figure #8
12 Volt 195 AH
All 6 Volt
Poly Case Batteries
330 AH, 6 Volt
Black Rubber Case Battery