HEAVY DUTY BATTERY BOOSTERS / CHARGERS MODEL Nos.
SPECIFICATIONS MODEL 260 330 420 Supply Voltage 230 230 230 Max Charge (Amps) 30 50 (cont) 60 (cont) Max Boost (Amps) 250 300 400 Boost/Charge (Volts) 12/24 12/24 12/24 Internat Fuse Rating 250A 300A 400A EM22220009 EM22220011 EM22220012 6225051 6225051 6225051 Internal Fuse Part No. Part No. For Spare Parts and Service, please contact your nearest dealer, or CLARKE International, on one of the following numbers.
Thank you for purchasing this CLARKE Battery Charger. These units are suitable for charging and boosting 12 or 24 Volt lead acid batteries. Before attempting to operate the unit, please read this instruction manual thoroughly, and follow all directions carefully. By doing so you will ensure the safety of yourself, and others around you, and at the same time, you should look forward to the unit giving long and trouble free service.
IMPORTANT: SAFETY PRECAUTIONS PLEASE READ BEFORE USING THIS UNIT 1. WARNING: Some electronic equipment can be damaged by boost charging or use of start facility. Check your vehicle handbook before using your Start āNā Charge. If in doubt consult the vehicle manufacturer. Nevertheless, you should not operate this equipment unless you are fully conversant with vehicle electrical systems, and battery charging techniques. 2.
ELECTRICAL CONNECTION Connect the three core mains lead to a suitable industrial supply isolator, or heavy duty plug. These chargers must be connected to a supply having a rated capacity of greater than 13 Amps. WARNING: A 13 Amp (BS1363) plug is not suitable.
PROCEDURE FOR NORMAL CHARGING NOTE: All references in brackets refer to Fig. 1 1) Before charging or boosting, ensure that the cells are filled with electrolyte to the correct level by adding distilled water where necessary. 2) Where appropriate we recommend that the non-earthed lead on the battery is disconnected prior to charging. It is possible that damage may occur to any electronically controlled system fitted to the vehicle such as engine management, anti-theft alarm, alternator etc.
Notes on charging procedure. * A complete charge is best done slowly in order to protect your battery We recommend the charging ratebe no more than 10% of the battery capacity rating (AH). eg. a typical battery has a rating of 40 Ampere Hours, therefore the charging rate should be 4 amps , and a complete charge will take 10 hours.
PARTS DIAGRAM BC260 8
PARTS LIST BC260 No. Description Qty Part No. 1 Switch 12 A 1 EM22205012 2 Switch Knob D.34 1 EM21690015 3 Timer 16A 250V 1 EM22215001 4 Timer Knob 1 EM21690034 5 Control Panel 1 EM33710004 6 Ammeter 30A 1 EM22600015 7 Thermostat + Holder 1 EM04600113 8 Rectifier 1 EM22400007 9 P.C.
PARTS DIAGRAM BC330 10
PARTS LIST BC330 No. Description Qty Part No. 01 Switch Knob D.34 1 EM21690015 EM22205028 02 Switch 1 03 Timer Knob 1 EM21690034 04 Timer 16A 250V 1 EM22215001 05 Controlpanel 1 EM33710004 06 Ammeter 50/400 A 1 EM22600019 07 Rectifier 1 EM22400014 08 Complete Thermostat+ Support 1 EM04600113 09 Contactor 24V 10A 1 EM22225005 10 Auxiliary Transformer 220/240V 1 EM44140016 11 PVC Input Cable 1 EM20220020 12 Lower Panel 1 EM33700028 13 Transfor.
PARTS DIAGRAM BC420 12
PARTS LIST BC420 No. Description Qty Part No. 1 Switch Knob 1 EM21690015 2 Switch 1 EM22205028 3 Timer Knob 1 EM21690034 4 Timer 16A 250V 1 EM22215001 5 Control panel 1 EM33710004 6 Ammeter 50/400 A 1 EM22600019 7 Rectifier 1 EM22400014 8 Complete Thermostat + Support 1 EM04600113 9 Contactor 24V 1 EM22225005 10 Auxiliary Transformer 220/240V 1 EM44140016 11 PVC Input Cable 3x2,5 m2,5 1 EM20220020 12 Lower Panel 1 EM33700028 EM44105016 13 Transfor.
WIRING DIAGRAMS BC260 BC330 14
BC420 15