Specifications
ELECTRICAL CONNECTION
Connect the three core mains lead to a suitable industrial supply isolator, or heavy
duty plug. These chargers must be connected to a supply having a rated
capacity of greater than 13 Amps.
WARNING: A 13 Amp (BS1363) plug is not suitable.
The maximum input amperages for these units are:
BC260 - 30amps, BC330 - 36amps, BC420 - 48amps
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in the mains lead are coloured in accordance with the
following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the flexible cord of this appliance may not correspond with the
coloured markings identifying terminals in your plug proceed as follows:
• Connect GREEN & YELLOW coloured cord to plug terminal marked with a
letter ‘E’ or Earth symbol ‘
’ or coloured GREEN or GREEN & YELLOW.
• Connect BROWN cord to terminal marked with a letter L or coloured RED
• Connect BLUE cord to terminal marked with a letter N or coloured BLACK
If in doubt, consult a qualified electrician.