HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: 5460600 & 5460595 OPERATING & MAINTENANCE INSTRUCTIONS GC0610
INTRODUCTION Thank you for purchasing this CLARKE Halogen Floodlight. Before attempting to operate the lamp, it is essential that you read this manual thoroughly and carefully follow all instructions given. In doing so you will ensure the safety of yourself and that of others around you, and you can also look forward to the lamp giving you long and satisfactory service. GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase.
GENERAL SAFETY WARNINGS 1. Please keep these instructions in a safe place for future reference. 2. Never carry out any alterations or modifications to this product. 3. Keep children and bystanders away from the work area. 4. Although the lamp may be used outdoors, do not leave it exposed to the elements. Never wash the lamp in water. 5. Never work in damp area without adequate insulation against electric shock. Avoid moving the lamp with wet hands or when standing on a wet or damp surface. 6.
ELECTRICAL CONNECTIONS WARNING! Read these electrical safety instructions thoroughly before connecting the product to the mains supply. Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230VAC 50Hz. Do not connect it to any other power source. This product may be fitted with a non-rewireable plug. If it is necessary to change the fuse in the plug, the fuse cover must be refitted.
COMPONENTS The CHL1260 floodlights include the following components: 2 1 6 5 4 3 1. 2 x Lamp Assemblies 2. 2 x Wire Guards 3. 1 x Tripod (1260T only) 4. 1 x Telescopic Column (1260T only) 5. 1 x Cross-Beam 6.
ASSEMBLY 1. Insert the telescopic column into the tripod from above, with the twist grip at the top. 2. Erect the stand, as shown in Fig 1 by slackening the locking knobs at the base and middle of the column and pulling the legs away from the column. The tripod will slide down the column and the legs move apart. 3. Re-tighten the locking knobs when the legs are spread correctly, ensuring the base of the column is seated in the locating ring. 4.
OPERATION The lamps can be switched on individually according to how much light is required from either one or both lamp units. 1. Press the left button to switch on one bulb. 2. Press the right button to switch on the other bulb. 3. Press both buttons to switch on both bulbs giving a total of 630W. TROUBLESHOOTING SYMPTOM Lamp will not operate POSSIBLE CAUSE REMEDIAL ACTION 1. Halogen bulb failed. Replace bulb. 2. Poor contact between bulb and socket.
MAINTENANCE GENERAL Clean the lens by wiping with a clean, dry cloth. DO NOT use abrasive cleaners/solvents. Check the power cable for wear or damage. If the plug is broken, withdraw the lamp from service & have it repaired by a qualified electrician. REPLACING THE BULBS 1. Ensure the lamp is switched off and isolated from the electrical supply by unplugging from the socket before attempting to replace a bulb.
REPLACEMENT PARTS Description Part No Description Halogen Bulb (230W) 5460610 Reflector HTCHL126003 Halogen Bulb (400W) 5460605 Transparent Cover HTCHL126004 Rubber Surround HTCHL126005 Mains Cable HTCHL126001 ON/OFF Switch HTCHL126002 Part No ENVIRONMENTAL PROTECTION At the end of its working life, do not dispose of this product or its components with general household waste. Any tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of appropriately.
TECHNICAL SPECIFICATION Feature Specification 13.5 kg (1260T - fitted to stand) Weight (unpacked) 8.
DECLARATION OF CONFORMITY 11