Technical data
14
4.5 Mechanical Installation
4.5.1 Locating the Heat Pump
Decide on a suitable location for the Heat Pump. This should ideally be in the back of a domestic garage,
or a utility room. It should not be placed in any inhabited space or near any noise sensitive areas. The
Compact emits limited noise and vibration, and should not be placed adjacent to, or below bedrooms or
occupied spaces. Take into account the “Recommended Clearances” when finalising the location.
Check the appliance for transport damage. Under no circumstances should a damaged appliance be
operated or installed.
Position the appliance on a firm, level and substantial concrete base that will absorb vibration well away
from any occupied rooms
Ensure that the appliance does not stand on the electrical supply cable. If the supply cable is damaged, it
must be replaced.
Ensure all pipes and wires are adequately supported where necessary, pipes are properly insulated and
concentrations of inhibitor (where added) are correct. The appliance and any metal pipes should be prop-
erly earthed.
A water treatment device should be provided in hard water areas.
Approx.
900mm
High
550mm
550mm
150mm required. Ideally
550mm for hood removal if
required.
100mm
100mm 100mm
4.5.2 Recommend clearances
Fig 8 Heat Pump clearances