Technical data
18
4.6.1 Single Phase
4.6.1.1 Single Underfloor Control Unit
In all wiring diagrams the terminals marked ‘Reverse Cycle’ change the mode from heating to cooling (If
this option is fitted). This requires a volt free relay, open is heating mode, closed cooling.
The terminals marked ‘Fault’ are to provide remote indication that a fault has occurred within the heat
pump. This is a volt free relay and the internal relay will close if a fault occurs.
Fig 14 Heat pump wiring—
Single Underfloor Manifold
230 Vac 50Hz power supply via a
Type D MCB in the buildings
distribution Board
Timeclock input.
Refer to Manufacturers Literature
Thermostat inputs.
Refer to Manufacturers Literature
Underfloor
Electric Actuator
Output
Refer to
Manufacturers
Literature
Boiler
Relay
DHW time
clock
DHW
Valve
Fault
Reverse
Cycle
Heat Pump Wiring Terminal block
Enable Signal connection is supplied with a temporary link across it . This should be
removed after commissioning and connection to the heating control system.
(Terminals 1 and 2)
Control Unit Power Supply