Technical data

21
4.6.3 Weather Compensation (Optional)
All Vent-Axia Compact Heat Pumps are supplied with Weather Compensation as standard. This facility will
reduce the return water set-point against a schedule of external ambient temperatures. In more simple
terms, the temperature of water flowing into the building’s radiators or underfloor heating is reduced in
mild weather, which allows the heat pump to run more efficiently. This is particularly important with
radiators, as much higher temperatures are required. In cold weather, many people already turn up the
temperature of water flowing from their boiler by hand and are therefore weather compensating their
heating system manually.
In the UK, the use of banded tariffs such as Economy 7, or more especially Economy 10, makes the use of
weather compensation on heat pumps unlikely to give any significant cost savings and can actually
increase the cost of running a heat pump. This is because during a banded and cheaper rate of electricity
it is desirable to run the heat pump at its maximum heat output so that as much heat is forced into the
building as possible, whilst being careful not to overheat it in milder weather.
For this reason, Vent-Axia Heat Pumps are supplied with the required sensors for installation, however the
function is disabled in the software and it is recommended that this function is not enabled. Tariffs might
possibly change in the future and so to enable weather compensation (if required) on your heat pump you
can contact our Technical department, who can run through the reprogramming procedure.
The weather compensation sensor is supplied in a small waterproof enclosure.
This sensor needs to be fixed to a North-facing wall, and connected with 2 core 0.5 mm cable, unshielded,
to the heat pump. The cable should be routed inside the heat pump case and left coiled up inside, with
the small green terminal block attached. The weather compensation should then be left disabled. If
weather compensation is required contact Vent-Axia Technical Department.
Do not disconnect or connect any terminal blocks until Vent-Axia Technical Department has been con-
tacted on 01293 441523.
Small green terminal
block
Weather compensation
sensor
Waterproof container
sensor
Green Terminal
block
Main terminal block
Fig 19 Weather
compensation sensor