CERAMIC HEATER Model: Devil 350 Part No: 6920262 OPERATING & MAINTENANCE INSTRUCTIONS GC11/11rev1
INTRODUCTION Thank you for purchasing this CLARKE Ceramic Heater. Please read this manual thoroughly and follow the instructions carefully. Before attempting to use the heater, thoroughly familiarise yourself with the heater & its operation. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to the heater giving you long and satisfactory service.
GENERAL SAFETY RULES WORK AREA 1. This heater is for INDOOR USE ONLY. 2. Do not expose the heater or power cable to rain or wet conditions. Any water entering the heater will increase the risk of electric shock. DO NOT use this heater in a bathroom, shower room or any other wet environment. 3. NEVER locate the heater near combustible materials such as curtains, furniture etc. Allow at least 1 metres clearance. 4. DO NOT locate the heater close to an adjacent wall or low ceiling.
3. ALWAYS disconnect from the mains supply before moving the heater, or performing any cleaning or maintenance tasks. 4. Keep the mains cable well away from machines and ensure an adequate electrical supply is close at hand so that the operation is not restricted by the length of the cable. 5. Inspect the mains cable regularly for signs of damage. DO NOT use if it is damaged, and ALWAYS keep it away from the source of heat. 6. Check the heater for damage before use.
ELECTRICAL CONNECTIONS WARNING! Read these electrical safety instructions thoroughly before connecting the product to the mains supply. Before switching the machine on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate using 230 VAC mains power. Connecting it to any other power source may cause damage. This product may be fitted with a non-rewireable plug.
UNPACKING AND ASSEMBLY Before assembling, please check contents against the following list and advise your dealer immediately if any parts are missing. 1 x Heater Handle 2 x Legs 1 x Handle 6 x Screws (supplied fitted) Screws 1. Remove the screws from their locations in the heater and use them to attach each leg. Legs 2. Repeat with the two remaining screws to fit the handle as shown. 3. DO NOT use the heater without fitting the legs. INSTRUCTIONS FOR USE 1.
CLEANING & MAINTENANCE ALWAYS allow the heater to cool down for at least 15 minutes and disconnect it from the mains supply before performing any maintenance tasks. PERIODICALLY 1. Inspect the mains cable for damage. Undue heat will cause the cable to stiffen and crack. If this is found, have the cable replaced. Check cable routing and ensure it is well away from the heat source. 2.
FAULT FINDING Problem Heater does not operate, although plugged in and switched on. Heating element glowing hot.* *Please note that the image on the carton shows a glow for illustration purposes only. Possible Cause Remedy Plug is loose/bad connection. Pull the plug out & check the connection of the plug and socket. Fuse blown Replace if necessary and investigate cause. If fuse blows re p e a t e d l y , c o n s u l t y o u r C L A R K E dealer. No power at socket outlet.
COMPONENT PARTS No Description 1 Front Guard 2 Part No No Description WSDEV35001 9 Part No T ip-over Switch WSDEV35009 M6x15 Pan Pozi Screw WSDEV35002 10 ON/OFF Switch WSDEV35010 3 Top Panel WSDEV35003 11 Casing WSDEV35011 4 Heat Element WSDEV35004 12 S/t Screw-small WSDEV35012 5 Neon Indicator WSDEV35005 13 Power Cable & Plug WSDEV35013 6 Reflector Panel WSDEV35006 14 Cable Clamp WSDEV35014 7 No10x1/2" Pan Pozi WSDEV35007 15 Leg WSDEV35015 8 Handle WSDEV35008 16 En
TECHNICAL SPECIFICATION Part No 6920262 Weight 5.45 kg Dimensions (L x W x H) 375 x 370 x 560 mm Max. Heat Output 1200/2400 W Rated Input Current 10.5 A Supply Voltage 230v / 50 Hz / 1 ph Fuse rating 13 A Insulation Class IP20 Please note that the details and specifications contained herein, are correct at the time of going to print. However, CLARKE International reserve the right to change specifications at any time without prior notice.
DECLARATION OF CONFORMITY 11 Parts & Service: 020 8988 7400/E-mail:Parts@clarkeinternational.com or Service@clarkeinternational.