ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015 Part Nos: 6925218, 6925220, 6925225, 6925230 & 6925235 OPERATING & MAINTENANCE INSTRUCTIONS GC1011
INTRODUCTION Thank you for purchasing this CLARKE Electric Fan Heater. Please read this manual thoroughly and follow the instructions carefully. Before attempting to use the heater, thoroughly familiarise yourself with the heater & its operation. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to the heater giving you long and satisfactory service.
TABLE OF CONTENTS INTRODUCTION .................................................................................. 2 GUARANTEE ........................................................................................ 2 ENVIRONMENTAL PROTECTION ......................................................... 2 SPARE PARTS & SERVICING CONTACTS ............................................. 2 TABLE OF CONTENTS .......................................................................... 3 GENERAL SAFETY RULES .............
GENERAL SAFETY RULES WORK AREA 1. These heaters are for INDOOR USE ONLY. 2. Do not expose the heater or power cable to rain or wet conditions. Any water entering the heater will increase the risk of electric shock. DO NOT use this heater in a bathroom, shower room, in the vicinity of a swimming pool, or any wet environment. 3. NEVER locate the heater near combustible materials such as curtains, furniture etc. Allow at least 1 metre clearance. 4. DO NOT locate the heater close to an adjacent wall or ceiling.
3. Keep the mains cable well away from machines and ensure an adequate electrical supply is close at hand so that the operation is not restricted by the length of the cable. 4. ALWAYS disconnect from the mains supply before moving the heater or performing any maintenance tasks. 5. ALWAYS use ONLY in an upright position. 6. Inspect the mains cable regularly for signs of damage. DO NOT use if it is damaged, and ALWAYS keep it away from the source of heat. 7. Check the fan heater for damage before use.
ELECTRICAL CONNECTIONS DEVIL 6002 (2KW)AND 6003 (3KW) HEATER UNITS These models are provided with a 13 amp BS 1363 plug, fitted with a 13amp fuse and MUST be connected to a standard, 230 Volt (50Hz) electrical supply, preferably through an approved plug, or a suitably fused isolator switch. E WARNING! Read these electrical safety instructions thoroughly before connecting the product to the mains supply.
Plug must be BS1363/A approved Earth (Green and Yellow) Always fit a 13 Amp fuse. Neutral (Blue) Live (Brown) Ensure that the outer sheath of the cable is firmly held by the clamp We strongly recommend that this machine is connected to the mains supply via a Residual Current Device (RCD). If in doubt, consult a qualified electrician. DO NOT attempt repairs yourself.
OPERATION The Devil range of fan assisted electric heaters are suitable for household (Devil 6002 & 6003 only) or workshop/factory use. They incorporate a thermostat which detects the temperature of the room air and controls the heater to maintain a pre-selected temperature between 0 & 40°C. A manually reset thermal cutout is provided for safety in the event of overheating on the 6005, 6009 & 6015 models. The 2kw and 3kw units are fitted with a self-resetting thermal cutout.
3-position fan speed control thermostatic temperature control The thermostat will then switch the heater on and off automatically to control the room temperature according to the pre-set value, maintaining a constant room temperature. When using the heater to warm a cold room, first turn the thermostat to MAX and run the heater on full power until the room temperature reaches the required value, then turn the thermostat anti-clockwise until it switches off.
Reset Thermostatic temperature control 3-position fan speed / temperature control The thermal cutout may also operate if the heater is shut down without allowing to cool sufficiently. If subsequently, the heater fails to start, press the RESET using a suitable tool and try again.
FAULT FINDING Problem Possible cause Plug is loose/bad connection. Heater does not operate, although Fuse blown. plugged in with the switch and ther mostat switched on. Heating element glowing hot. Replace if necessary and investigate cause. If fuse blows re p e a t e d l y , c o n s u l t y o u r CLARKE dealer. No power at socket outlet. Insert the plug in a suitable socket. Input voltage too high or too low. Use a power supply in a c c o rd a n c e w i t h t h e r a t i n g on the label.
PARTS DIAGRAM DEVIL 6002 NO CODE DESCRIPTION Qty NO CODE 1 N/A Handle 2 N/A 3 1 13 N/A Side Panel (RH) 1 Top Panel 1 14 N/A Securing Rings 1 N/A Chassis Panel 1 15 C X D E V 600207 Switch 1 4 C X D E V 600201 F an 1 16 CXDEV600208 Room Thermostat 2 5 C X D E V 600202 Electric Motor 1 17 C X D E V 600209 Control Knob 1 6 N/A Rear Grill 1 18 Control Panel 1 7 C X D E V 600203 Power Cable 1 19 CXDEV600210 Heating Elements 1 8 N/A Side Panel (L/H) 1 20
PARTS DIAGRAM DEVIL 6003 NO CODE DESCRIPTION Qty 1 N/A Support Leg 2 13 C X D E V 600305 2 N/A Top Panel 1 14 CXDEV600306 Fan Control Knob 1 3 N/A Chassis Panel 1 15 N/A Front Panel 1 4 C X D E V 600301 F an 1 16 N/A Mounting Packer 2 5 C X D E V 600302 Motor 1 17 N/A Washer 1 6 N/A Retaining clips 2 18 CXDEV600307 Power/Fan Speed Controller 7 N/A Rear Panel 1 19 C X D E V 600308 8 C X D E V 600303 Power Cable 1 20 9 N/A Side Panel (RH) 1 21 10 N/A
PARTS DIAGRAM DEVIL 6005 NO CODE DESCRIPTION Qty 1 N/A Support Leg 2 2 N/A Top Panel 3 N/A 4 NO DESCRIPTION Qty 12 C X D E V 600503 Heating Element 2 1 13 C X D E V 600504 Front Grille 1 Chassis Panel 1 14 CXDEV600505 Fan Control Knob 1 C X D E V 600501 F an 1 15 N/A Front Panel 1 5 C X D E V 600502 Motor 1 16 N/A Plastic Plug 1 6 N/A 5-Pin Socket 1 17 N/A Support Bar 1 7 N/A Rear Panel 1 Power/Fan Speed 18 C X D E V 600506 Controller 8 N/A Cable Ent
PARTS DIAGRAM DEVIL 6009 NO CODE DESCRIPTION Qty NO 1 N/A Support Leg 2 12 CXDEV600903 Heating Element 2 2 N/A Top Panel 1 13 C X D E V 600904 Front Grille 1 3 N/A Chassis Panel 1 14 C X D E V 600905 Control Knob 2 4 C X D E V 600901 F an 1 15 N/A Front Panel 1 5 C X D E V 600902 Motor 1 16 N/A Support Bar 1 6 N/A Cable Entry 2 17 N/A Closing Panel 1 7 N/A Rear Panel 1 Power/Fan 18 CXDEV600907 Speed Controller 8 N/A Plastic Plug 1 19 C X D E V 600908
PARTS DIAGRAM DEVIL 6015 NO CODE DESCRIPTION Qty 1 N/A Support Leg 2 2 N /A Top Panel 3 N/A 4 DESCRIPTION Qty 13 CXDEV601504 Front Grille 1 1 14 CXDEV601505 Control Knob 1 Chassis Panel 1 15 N/A Front Panel 1 CXDEV601501 Fan 1 16 N/A Heat Shield 2 5 CXDEV601502 Motor 1 17 N/A Closing Plate 1 6 N/A Angle Bracket 1 18 CXDEV601506 Speed Controller 1 7 N/A Rear Panel 1 19 CXDEV601507 Temperature Controller 1 8 N/A 5-Pin Socket 1 20 N/A LH Side Pan
TECHNICAL SPECIFICATION Item Published Specification Model Devil 6002 Devil 6003 Devil 6005 Devil 6009 Devil 6015 Part No 6925218 6925220 6925225 6925230 6925235 Weight 3.6 kg 5.5 kg 7.0 kg 9.0 kg 14.4 kg Dimensions (d x w x h) mm 225x200x425 295x265x425 295x305x25 350x335x465 400x345x535 0.025kw(fan 95w(fan only) only) Input Wattage 0.6kw(setting 1) 1.5(setting 1) 2.5(setting 1) 4.5(setting 1) 5kw(setting 1) 3.0(setting 2) 5.0(setting 2) 9.0(setting 2) 10kw(setting 2) (kw) 1.