Specifications

9
Check the oil level, which should be midway across
the sight glass, as shown in Fig.3.
Remove the breather and top up, using a funnel, with
Clarke compressor oil (SAE40).
When replacing the breather, unscrew the cap and
check the filter for cleanliness as shown in Fig.4. if
it is badly contaminated, it should be replaced,
otherwise, it may be washed gently in soapy
water, rinsed thoroughly and dried before
Fig. 4
Fig.3
ROUTINE MAINTENANCE
IMPORTANT: Before carrying out any of this service work, always disconnect the
machine from the mains supply, drain the air receiver and, if necessary, allow the
machine to cool down before starting work.
Daily
Before use, always open the drain valve to ensure that any condensate, which
may have accumulated, is drained off.
Monthly
It is important to keep the Compressor clean, with the help of a small soft brush
and vacuum cleaner. In particular, the air intake filter should be inspected at least
MONTHLY, and more often in dusty conditions, so that it is always kept free of any
dirt particles, which if not cleaned away will
affect the performance of the machine.
To clean the air intake filter, first remove the
cover which has a bayonet fitting - turn the
cover anticlockwise and pull off, then carefully
prise out the paper element with its holder -
shown in fig.2. Clean the complete filter housing
using a cloth or brush.
If the filter is clogged or badly blackened, it should
be replaced. It is not possible to wash the filter
Fig.2