HP SWIMMING POOL PUMP Model SPP10 Part No: 7175030 OPERATING & MAINTENANCE INSTRUCTIONS GC12/11
INTRODUCTION Thank you for purchasing this CLARKE swimming pool pump. Before attempting to operate the pump, it is essential that you read this manual thoroughly and carefully follow all instructions given. In doing so you will ensure the safety of yourself and that of others around you, and you can also look forward to the pump giving you long and satisfactory service.
GENERAL SAFETY PRECAUTIONS WARNING: The SPP10 pump is not a submersible pump. On no account should it ever be immersed in water. Always connect the pump to an earthed power supply via a RCD. 1. ALWAYS keep the pump room clean and well lit. Floors should always be kept clear. Cluttered or dark areas invite accidents. 2. NEVER over-reach. Keep your proper footing and balance at all times when installing or maintaining the pump. 3. NEVER direct any water discharge towards electrical wiring or equipment. 4.
ELECTRICAL CONNECTIONS WARNING! Read these electrical safety instructions thoroughly before connecting the product to the mains supply. Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230VAC 50Hz. Connecting it to any other power source may cause damage. This product may be fitted with a non-rewireable plug.
INSTALLATION Because of the variety of possible installations, no plumbing accessories are supplied with your pump, however accessories are available from your nearest CLARKE dealer. Contact your CLARKE dealer for further information, or CLARKE International Sales Department on 01992 565333. Note: It is recommended that the end user should consult a qualified installer if there are any doubts as to the suitability of this product for a particular installation.
ELECTRICAL CONNECTION The pump should be located at a safe distance, (usually 2 metres), away from the pool, and the power supply should be at least 3.5 metres from the pool. If in doubt, please contact your electrical specialist and refer to the International Electrical Commission (IEC) standard, (Electrical Installations for Buildings-part 7), referring to ‘swimming pools and other basins’.
OPERATION 1. Open any valves in the pipeline. Wrench 2. If operating the pump for the first time, unscrew the filter cover on top of the pump using the wrench supplied and prime the pump by filling completely with water. Note: The pump is only self- priming when filled with water. Refilling is only necessary if the pump has been drained, or if all the water has been lost. Fig 3 3. Connect to the power supply and switch on. Water should start to flow through the system.
MAINTENANCE The only maintenance required is a regular inspection to ensure that debris is not blocking the passage of water through the pump. Clean the filter basket periodically after closing any inlet and delivery valves and removing the filter cover, using the wrench provided. Lift out the filter basket and clean it in water, check the cover O-ring is in good condition before reassembly.
TROUBLESHOOTING PROBLEM CAUSE SOLUTION No mains supply Check fused power supply and replace fuse if necessary (check fuse rating). Check circuit breaker. Impeller seized/blocked. Disconnect pump from mains supply. Investigate cause and clear blockage. Air leaks through suction hose joints (damaged hose, broken clamp, damaged/ill-fitting gasket) Repair connections/replace hose as necessary. Blocked inlet hose. Check pipeline and pool skimmer for blockage. Check any inlet valve fitted is fully open.
TROUBLESHOOTING PROBLEM CAUSE SOLUTION Undue vibration or noise. Excessive flow of water. Decrease flow of water. by adjusting inlet/outlet valves in system. Resistance in inlet pipe caused by obstruction. Check pipe and clean out as necessary. Loose rotating component Return to your dealer for repairs. Installation of pump is unstable. Stop pump and re-position. Air pocket in pump or pipeline. Release drain plug in impeller housing to release air.
TECHNICAL SPECIFICATION SPP10 Weight 9.95 kg Dimensions (L x W x H) 610 x 190 x 316 mm Max Flow 366 L/min Max Head 15 m Operating Temperature 35°C Water Classification Swimming Pools/Clean Water Return Valve Type Flap type at outlet Inlet & Outlet Size 50 i/d / 56 o/d (mm) Power Supply 220-240V @ 50Hz Output Power 1HP (750 W) Sound Pressure Level 68.8 dB LpA Sound Power Level 75.
PARTS LIST No Description Part No qty 1 Drain Plug ZGSPP1001 2 2 Sealing O-Ring ZGSPP1002 2 No Description Part No qty 32 Sealed Sheath ZGSPP1032 1 33 Cable Clip ZGSPP1033 1 3 Pump Casing ZGSPP1003 1 34 X-Hd Machine Screw ZGSPP1034 2 4 Bolt ZGSPP1004 2 35 Wave Washer ZGSPP1035 1 5 Washer ZGSPP1005 2 36 Gasket ZGSPP1036 1 6 Sealing Ring ZGSPP1006 1 37 Tamper-proof Screw ZGSPP1037 4 7 Diffuser ZGSPP1007 1 38 Cover Panel ZGSPP1038 1 8 Impeller ZGSPP1008 1
PARTS DIAGRAM 13 Parts & Service: 020 8988 7400/E-mail:Parts@clarkeinternational.com or Service@clarkeinternational.
DECLARATION OF CONFORMITY 14 Parts & Service: 020 8988 7400/E-mail:Parts@clarkeinternational.com or Service@clarkeinternational.
DECLARATION OF CONFORMITY 15 Parts & Service: 020 8988 7400/E-mail:Parts@clarkeinternational.com or Service@clarkeinternational.