TFC 400 OPERATOR MANUAL Clarke MODEL 56380773 11/09 Rev C Document Number 56380889
IMPORTANT SAFETY INSTRUCTIONS This machine is only suitable for commercial use, for example, in hotels, schools, hospitals, factories, shops, and offices other than normal residential housekeeping purposes. When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.
INTRODUCTION This manual will help you to get the most from your Clarke All Purpose Cleaner. Read it thoroughly before operating the machine. This product is intended for commercial use only. PARTS AND SERVICE Repairs, when required, should be performed by Clarke service personnel using original replacement parts and accessories. Call Clarke for repair parts or service. Please specify the Model and Serial number when calling about your machine.
KNOW YOUR MACHINE DESCRIPTIONS Operator Handle (1): Operator holds onto this handle to move the machine from one location to another. Solution Tank Lid (2): This lid screws off so the tank can be filled. The solution fill hose is tethered to the lid, and hangs inside the arm of the Operator Handle. Tools & Accessories (3): Various accessories can be stored on the machine. Basket (4): This lift-off carrying basket sits on top of the round lid on the Recovery tank.
KNOW YOUR SWITCH PLATE 2 1 I 4 O O 3 Vacuum Switch (1): turns on the vacuum motor. Chemical Valve (2): switches between the two chemical containers. When the selector is pointed straight down, the valve is off and neither chemical is selected. When the selector is pointed directly towards one or the other symbols, that chemical is selected. Solution Pump Switch (3): turns on the solution pump.
OPERATION 1) Insert the appropriate metering tips into the chemical feed lines (see illustration, page 5). 2) Fill the holding tank with warm water (not exceeding 120 °F). Do not add any chemical to the tank. 3) Prepare the area for cleaning by emptying waste receptacles, clearing debris, removing paper products, blowing out vents, and sweeping floors. 4) Connect the 25 ft power cord to the pig-tail on the rear of the machine. Test the GFCI on the power cord before each use.
19 10 28 56380773 TFC-400 7 8 1 9 2 18 29 6 20 15 26 21 17 5 16 22 11 3 23 24 12 23B 13 27 4 11-04-09 25 14
PART LIST ITEM PART No.
TOOLS Tool Kit, standard, complete -- # 56380937 7 10 1 3 4 2 8 5 9 6 1 2 3 4 5 6 7 8 9 10 11 12 56380854 56380853 56380838 56380855 56108027 56108028 56108072 56380802 56108024 56380852 56380805 56380938 Squeegee, hand-held, 12” Handle, 12”, for hand squeegee Solution hose, complete, 25 ft Brush, dual surface, polypropylene Wand, two-piece, snap fit Squeegee,14’, for floor Spray gun, complete Metering tip kit, two each of seven sizes Priming hose assembly, for 400 psi pump Handle, black, 54” Recov
MAINTENANCE 1) Use only approved chemicals at the recommended mix ratios. All chemicals should be added through the feed system and NOT added directly to the water in the solution tank to prevent possible damage to the pump, seals, or other components. 2) For optimum performance, flush the Chemical Feed lines after every job by replacing the chemical containers with containers of clear water and spraying through the gun until the fluid stream is clear. See the Maintenance Schedule, below.
NOTES: 11
Clarke® U.S. WARRANTY This Clarke Industrial/Commercial Product is warranted to be free from defects in materials and workmanship under normal use and service for a period of three years from the date of purchase, when operated and maintained in accordance with Clarke’s Maintenance and Operation instructions. This warranty is extended only to the original purchaser for use of the product. It does not cover wear parts such as electrical cable, rubber parts, hoses, and motor brushes.