Owner's manual

2
© Copyright 2012. All rights reserved.
P R E L I M I N A RY
Re-circulation
Baffle
Inflow
Air-lift Pump
Blower
Air-lift Pump
Backwash
Aeration
Sludge return
Baffle
Effluent
Top View
1
2
4
3
Effluent
Side View
Wall opening
Inflow
Recirculation
Backwash Mechanism
Wall opening
Baffle
Baffle
Recirculation
W.L
G.L.
G.L.
W.L
1
2
3
4
W.L
6 “ (152 mm) stone or concrete pad
The Fusion
®
is simple in design, yet advanced in its wastewater
treatment ability. The design has been rened over many years
of intense research and development in an effort to perfect
this superior treatment system. Fusion
®
systems are 90% -
95% efcient at treating wastewater. This is nearly twice as
effective as a traditional septic tank, which is approximately
50% efcient. This high degree of treatment helps to protect
both your personal property and the environment.
The Fusion
®
utilizes a combination of anaerobic (without
oxygen) and aerobic (with oxygen) biological processes to treat
wastewater. As wastewater enters the Fusion
®
, it is broken
down and becomes food for biological organisms operating
within the unit. The rst chamber serves to separate grease
and large solids from the liquid. In the second chamber, plastic
media with large surface areas are used to increase contact
between water and benecial bacteria to optimize treatment. A
small linear air blower is used to move air (oxygen) into the third
chamber for the aerobic process. The nal efuent leaving the
system will have been treated to secondary quality efuent and
will average *9 mg/L CBOD
5
and 9mg/L TSS.
* Based on NSF Standard 40 testing.
HOW A FUSION
®
SERIES TREATMENT SYSTEM WORKS
Anaerobic Chamber -
Organisms adhere to xed lm
media and digest waste
Recirculation Line
Storage
Chamber
Inlet Pipe
4” PVC
SCH 40 (DN 100)
Tank - Compression
Molded Fiber
Reinforced Plastic
Sedimentation
Chamber -
Separates bulk solid
and grease waste
Outlet Pipe
4” PVC
SCH 40
Aeration Chamber
Floating/Circulating
Filter Media -
“Fluidized Bed”
Invigorates aerobic bacteria
Sludge Return Line
Figure 1 - The following diagram will help you to better understand the process:
Figure 2 - Schematic diagram of the Fusion
®
Treatment System