Owner's manual

4
© Copyright 2012. All rights reserved.
P R E L I M I N A RY
FUSI O N TREA TMENT S Y STEM
600 GALLONS/DAY
450
GALLONS/DAY
800 GALLONS/DAY
BLO W ER S E RV I E P ART S
COMPLETE BLOWER: P/N 019617
BLOWER DIAPHRAGM: P/N 018848
BLOWER FILTER: P/N 018849
MFGDATE09/07
Manufacturer:
Clarus Environmental • 3649 Cane Run Road
Louisville, KY 40211•1-877-244-9340
toll free
ZF 450
ZF 600
ZF 800
P/N 018860-B
®
Certified to
NSF - ANSI
Standard 40
®
The Fusion
®
comes with an alarm panel (see Figure 6) that is
designed to activate an audible buzzer and red beacon light on
top of the panel if there is a drop in air pressure, if a high water
alarm condition occurs, or if the blower does not cycle between
recirculation and backwash modes within the preset time. (Note:
Alarm panel can only function as long as there is electrical power
supplied to the panel)
You may from time to time check the proper operation of the
alarm panel by toggling the black switch on the side of the panel
to “test”. The buzzer will sound and the red beacon will light as
long as you hold the switch in the test position. Release the
switch for normal operation.
A dataplate similar to the one in Figure 5 is located on the blower
housing and the alarm panel. There is important information about
the Fusion
®
on the dataplate, such as the part number, model
number, serial number, and hydraulic capacity. Please make a
note of this information for future reference or in case you should
need to contact your Fusion
®
maintenance provider.
The contracting installer must mark the installed model number
on the dataplate, the blower housing and the alarm control panel.
Figure 6
P/N
WARNING!
RED BEACON
SILENCE/TEST
SWITCH
BUZZER
FUSION
DATAPLATE
sk2649
LEAKY FIXTURES
It is very important to monitor all water xtures in the home for leaks
and drips and repair them immediately. Leaks can cause tremendous
water use and use may hydraulically overload your Fusion
®
system and
reduce its treatment efciency. Excessive water use may also overload
your soil absorption eld and cause failure.
HIGH USE WATER DEVICES
The draining of hot tubs and swimming pools into your Fusion
®
system
could cause hydraulic overloading and may reduce the treatment
efciency. Please drain these devices to another location. Contact
your local regulatory authorities or authorized Fusion
®
maintenance
provider for more information. The use of large capacity single ll and
drain whirlpool bathtubs may also cause hydraulic overloading of your
Fusion
®
. Please limit the use of these types of tubs.
The Fusion
®
system is designed to continuously operate automatically
with little direct maintenance from the owner. Periodically, a check of the
blower area is recommended to ensure no debris obstructs the ventilation
or intake areas of the blower. Also, periodically test the control panel
as outlined under the alarm panel section. The owner should closely
monitor the types and amounts of substances and products used. Water
use should also be closely monitored to ensure proper operation of the
Fusion
®
system.
Periodically, more extensive maintenance must be performed. Your
authorized Fusion
®
maintenance provider will oversee this service. The
name of the maintenance provider can be recorded on the front of this
document and should also be located on the alarm panel. For more
information see the Operation and Maintenance section of the manual.
The owner should only perform minimal routine maintenance on the Fusion
®
such as clearing debris from around blower housing (leaves, snow, and
grass clippings). The Fusion
®
should also be protected from excessive
weight such as vehicular trafc. Trees and bushes should not be planted
in close proximity to the Fusion
®
. The Fusion
®
should be accessible to
maintenance personnel and the riser lids must never be buried.
ALARM PANEL
DATAPLATE
FLOODING
If ooding of the Fusion
®
occurs and the blower
or the alarm panel is submerged, please disconnect power at the
circuit breaker. DO NOT try to reconnect power to either the blower
or alarm panel once it has been submerged. Immediately contact your
authorized Fusion
®
maintenance provider to inspect the Fusion
®
, the
blower, and the alarm panel. Your maintenance provider will repair or
replace the components as needed.
Figure 5
SYSTEM CARE
sk2933
Figure 7
1
BLOWER
GND LUG
DISNF
ALARM
TB2
L1
N
GND
2 3 4 5 6 7 8
HIGH WATER
ALARM
120 VAC
INCOMING
POWER
*FOR ILLUSTRATION PURPOSES ONLY*
REFER TO SCHEMATIC LOCATED IN
PANEL FOR INSTALLATION
The Fusion
®
system is designed to function even if wastewater does
not enter it for extended periods of time. The power to the blower
must remain on during this time for the system to function properly.
Weekend use will not harm the system as long as the blower is on.
Should seasonal use require a complete shut down of the property,
then it is recommended that the blower be turned off. It is important
to start up the system in advance of actual occupancy to allow for
normal treatment to resume. Please contact your authorized Fusion
®
maintenance provider for further information concerning shut down and
startup of the Fusion
®
. You may also contact your maintenance provider
for the shut down and startup services.
INTERMITTENT USE