C:\manuals\Uni-Gov-V6-107490
PSI Transducer
%ODFN*URXQG
5HG9'&
:KLWH6LJQDO
%
%
%
%ODFN*URXQG
5HG9'&
:KLWH6LJQDO
$
%
&
7UDQVGXFHU&RQQ
H
Shielded Cable
Pressure Transducer cable and connector.
100581
P165-5276
300 PSI
True
Pressure
Transducer
Voltage
Low mV
0-22 680
23-34 988
35-44 1168
45-54 1307
55-64 1427
65-74 1567
75-84 1708
85-94 1846
95-104 1988
105-114 2105
115-124 2243
125-134 2384
135-144 2522
145-154 2664
Make certain that the
weather seal is in place
before inserting into the
transducer.
!
WARNING
Pressure Transducer
Locate the pressure transducer where it can read pump discharge pressure without
turbulence.
A ‘tee’ at the Master Discharge Gauge would be a good location, this should also
serve to reduce vibration and shock to the transducer. Threads are 1/4 NPT and a
sealant should be applied prior to installation. When tightening the transducer, apply
torque to the 1-1/4” hex flange of the transducer, not the body.
Every effort should be made to eliminate the chance for moisture entering the trans-
ducer connector including immediate connection of the transducer harness connec-
tor after installation.