User Manual
FORM-ENG-0018 REV A 05-27-03
PAGE
19 OF 30
TECHNICAL DATA SHEET
DATE 4/9/2009
PRODUCT GROUP
THROTTLE CONTROL
P/N 118710 REV 1.00
607 NW 27th Ave
Ocala, FL 34475
Ph: 352-629-5020 or 1-800-533-3569
Fax : 352-629-2902 or 1-800-520-3473
PRODUCT
TOTAL PRESSURE GOVERNOR PLUS (TPG+)
BY AMS
Manual P/N 118711
MENU ITEM DESCRIPTION DEFAULT MENU LEVEL
WARN PSI
Configure the yellow (warning) oil pressure setpoint
(only available when WARNINGS is set to Usr)
-
3*
CRIT PSI
Configure the red (critical) oil pressure setpoint
(only available when WARNINGS is set to Usr)
-
3*
XDCR Configures transducer type (300 or 600 psi)
300
3
FACTORY DFLT Resets parameters to factory default settings
3
GOV GAIN
Configures the RPM change requested per INC or DEC switch press
(Only available with message type ANLG)
15
4*
PRESS GAIN
Configures the pressure change requested per INC or DEC switch
press
3 PSI
4
DITHER
Configure the engine handshake
(Only available with message type PGN0)
NO
4*
LAG (∆PSI)
Controls the response of the pressure increase when the INC button
is held while in pressure mode.
(Not available with message type ANLG)
5 PSI
4*
PUMP HOURS Sets pump-engaged hours counter to a specified value
N/A
4
BCM1 VER
Configures the Scania BCM version
(Only available with message type SCAN)
1
4*
SCANIA MODE
Configures the Scania engine control type: NORMAL or STIFF
(Only available with message type SCAN)
NORMAL
4*
* Option dependent on other menu selections made