Engineering
Standards
Name
Identifier OEM Installation and Calibration
Engineering Standard Number
C1-105593
Four Output Tank Level
ISO 9001 CERTIFIED
E:\MANUALS\DIGITAL\TANKLEVEL\NEW T ANK LEVEL_ESN.P65_05062001
Connector information:
Connector Ter minal Lock
Deutsch DTM06-12SA 0462-201-20141(18-24 Ga.) WM-12S
1062-20-0122 (10-16 Ga.)
1 1/4 indication output 7 NC
2 NC 8 Transducer +5 VDC output
3 N C 9 Full indication output
4 3/4 indication output 10 1/2 indication output
5 Transducer Signal input 11 Transducer Ground output
6 NC 12 Ground
#10 Ring terminal Output Driver Pow er
LED Status
Red PWR System Power and Ground OK
Amber BUS Dr iver Power OK
Green COM Flashes 8X on power up and then steady
The module is waterproof and can be mounted in almost an y location. Avoid areas of Ex-
tremely high temperature (above 75 deg C) and/or high vibration.